- MX20066PU MX22060PU & MX19070PU Pump Manual 77-3331 EN [ English ]
MX22060PU-CMB/SMB
MX19070PU-CMB/SMB
INSTALLATION MANUAL
77-3331
MX22060PU-CMB MX22060PU-SMB
MX20066PU-CMX MX20066PU-SMX
MX19070PU-CMB MX19070PU-SMB
MX20066PU-CMX/SMX
MX22060PU-CMB/SMB
MX19070PU-CMB/SMB
Pump Assembly
MX20066PU-CMX/SMX
Patent 7,603,855
EN
This Declaration of Conformity / Incorporation is issued under the sole responsibility of the
manufacturer:
22/04/25
F. A. Sutter
Product Description / Object of Declaration:
This Product is designed for use with: Solvent & Waterbased Materials
104×××/AX160L-×/AX110L-×/AX200L-××/AX320××/
MMX4×××××/MMX12××××/MXL4×××××/MXL12××××/MX11
4×××/MX115××××/MX12X××××/MX19×××××/MX2×××××
×/MX68××××/MX8×××××.
Suitable for use in hazardous area: Zone 1/Zone 2
Representative authorised to compile the technical file President @. Binks France SAS
5 Place Pierre Semard, 94130 Nogent sur Marne , Paris, France
Executive President: Engineering and
Operations, Shoreview, MN, 55126. USA
Protection Level: II 2 G c X IIB T4
Ex h IIB T4 Gb X
Notified body details and role: Element Materials Technology Rotterdam B.V. (2812)
Lodging of ATEX Technical file
This Declaration of Conformity / Incorporation is issued
under the sole responsibility of the manufacturer:
Binks U.K. Limited,
Ringwood Road,
Bournemouth, BH11 9LH. UK
Machinery Directive 2006/42/EC
ATEX Directive 2014/34/EU
by complying with the following statutory documents and harmonised standards:
EN ISO 12100:2010 Safety of Machinery - General Principles for Design
EN 12621:2006+2010 Machinery for the supply and circulation of coating materials under pressure - Safety requirements
EN ISO 80079-36:2016 Explosive Atmospheres- Part 36:Non Electrical equipment for explosive atmospheres-Basic methods
and requirements.
EN ISO 80079-37:2016 Explosive Atmospheres- Part 37: Non Electrical equipment for explosive atmospheres - protection by
methods c, b and k.
EN 1127-1:2019 Explosive atmospheres - Explosion prevention - Basic concepts
Providing all conditions of safe use / installation stated within the product manuals have been complied with and also installed in accordance
with any applicable local codes of practice.
EU Declaration of Conformity
Signed for and on behalf of Binks
U.K. Ltd:
Document Part No.
.
77-3331 R2.0 (08/2025) 2/20 www.binks.com
EN
This Product is designed for use with: Solvent & Waterbased Materials
UKCA Declaration of Conformity
Product Description / Object of Declaration: 104×××/AX160L-×/AX110L-×/AX200L-××/AX320××/
MMX4×××××/MMX12××××/MXL4×××××/MXL12××××/MX11
4×××/MX115××××/MX12X××××/MX19×××××/MX2×××××
×/MX68××××/MX8×××××.
Suitable for use in hazardous area: Zone 1/Zone 2
Protection Level: II 2 G c X IIB T4
Ex h IIB T4 Gb X
Approved body details and role: Element Materials Technology Warwick Ltd. UK. (0891)
Lodging of UKEX Technical file
This Declaration of Conformity / Incorporation is issued
under the sole responsibility of the manufacturer:
Binks U.K. Limited,
Ringwood Road,
Bournemouth, BH11 9LH. UK
Signed for and on behalf of Binks
U.K. Ltd:
Document Part No.
.
This Declaration of Conformity / Incorporation is issued under the sole responsibility of the
manufacturer:
Supply of Machinery (Safety) Regulations 2008
Equipment and Protective Systems Intended for use in Potentially Explosive Atmospheres Regulations 2016
by complying with the following statutory documents and designated standards:
BS EN ISO 12100:2010 Safety of Machinery - General Principles for Design
BS EN 12621:2006+2010 Machinery for the supply and circulation of coating materials under pressure - Safety requirements
BS EN ISO 80079-36:2016 Explosive Atmospheres- Part 36:Non Electrical equipment for explosive atmospheres-Basic methods
and requirements.
BS EN ISO 80079-37:2016 Explosive Atmospheres- Part 37: Non Electrical equipment for explosive atmospheres - protection
by methods c, b and k.
BS EN 1127-1:2019 Explosive atmospheres - Explosion prevention - Basic concepts
Providing all conditions of safe use / installation stated within the product manuals have been complied with and also installed in accordance
with any applicable local codes of practice.
Executive President: Engineering and
Operations, Shoreview, MN, 55126. USA
F. A. Sutter
20/05/25
77-3331 R2.0 (08/2025) 3/20 www.binks.com
EN
Read the following warnings before using this equipment.
In this part sheet, the words WARNING, CAUTION and NOTE are used to emphasize important safety information as
follows:
WARNING CAUTION NOTE
Hazards or unsafe practices which could result in
severe personal injury, death or substantial property
damage.
Hazards or unsafe practices which could result in
minor personal injury, product or property
damage
Important installation, operation or maintenance
information.
WARNING
KEEP EQUIPMENT GUARDS IN PLACE.
Do not operate the equipment if the
safety devices have been removed.
STATIC CHARGE. Fluid may develop a static charge that must be
dissipated through proper grounding of the equipment, objects to be
sprayed and alll other electrically conductive objects in the dispensing
area. Improper grounding or sparks can cause a hazardous condition
and result in fire, explosion or electric shock and other serious injury.
NEVER MODIFY THE EQUIPMENT. Do
not modify the equipment unless the
manufacturer provides written
approval.
PROP 65 WARNING. WARNING: This product contains chemicals
known to the state of California to cause cancer and birth defects or
other reproductive harm.
PINCH POINT HAZARD. Moving parts
can crush and cut. Pinch points are
any areas where ther are moving
parts.
READ THE MANUAL. Before operating finishing equipment, read and
understand all safety, operation and maintenance information
provided in the operation manual.
AUTOMATIC EQUIPMENT. Automatic
equipment may start suddenly without
warning.
WEAR SAFETY GLASSES. Failure to wear safety glasses with side
shields could result in serious eye injury or blindness.
PROJECTILE HAZARD. You may be
injured by venting liquids or gases that
are released under pressure, or flying
debris.
DE-ENERGIZE, DE-PRESSURISE, DISCONNECT AND LOCK OUT ALL
POWER SOURCES DURING MAINTENANCE. Failure to de-energize,
disconnect and lock out all power supplies before performing
equipment maintenance could cause serious injury or death. KNOW WHERE AND HOW TO SHUT
OFF THE EQUIPMENT IN CASE OF AN
EMERGENCY.
NOISE LEVELS. The A-weighted sound level of pumping and spray
equipment may exceed 85 dB(A) depending on equipment settings.
Actual noise levels are available on request. It is recommended that
ear protection is worn at all times while equipment is in use.
PRESSURE RELIEF PROCEDURE.
Always follow the pressure relief
procedure in the equipment instruction
manual.
INSPECT THE EQUIPMENT DAILY. Inspect the equipment for worn or
broken parts on a daily basis. Do not operate the equipment if you
are uncertain about its condition.
OPERATOR TRAINING. All personnel
must be trained before operating
finishing equipment.
EQUIPMENT MISUSE HAZARD. Equipment misuse can cause the
equipment to rupture, malfunction or start unexpectedly and result in
serious injury. PACEMAKER WARNING. You are in the
presence of magnetic fields which may
interfere with the operation of certain
pacemakers.HIGH PRESSURE CONSIDERATION. High pressure can cause serious
injury. Relieve all pressure before servicing. Spray from the gun,
hose leaks or ruptured components can inject fluid into your body
and cause extremely serious injury.
IT IS THE RESPONSIBILITY OF THE EMPLOYER TO PROVIDE THIS INFORMATION TO THE
OPERATOR OF THE EQUIPMENT.
77-3331 R2.0 (08/2025) 4/20 www.binks.com
EN
The MX******* -CMX/SMX/CMB/SMB fluid pumps are designed for pumping a range of high viscosity
automotive and industrial fluids.
All variants have a flanged inlet connection for mounting onto a ram based dispensing system to pump
high viscosity materials such as mastic and panel sealants, liquid PVC, liquid sound deadening fluids and
other similar materials straight from a drum or other container.
-CMX/SMX variants additionally have a 'chop check' extension attached to the pump rod and extend below
the ram mount. This device consisting of a flap type valve on a disc is designed to be immersed in the
fluid within the drum / container. As the pump operates, this device moves up and down agitating the
fluid. This function is particularly useful for fluids with a thixotropic viscosity characteristic as this pre-
pump agitation helps reduce viscosity and improve fluid flow close to the pump inlet.
The fluid section is based on a double diameter, double seal rod / plunger pump design resulting in the
pump delivering fluid in both the up and down strokes. A ball check valve system ensures a precise,
smooth volume output. Tungsten carbide ball seats ensure maximum operating life between servicing.
The internal layout maintains high flow capacity with minimum pressure drop ensuring high efficiency.
Special surface treatments provide a smooth micro surface making cleaning and flushing easier.
Both sets of seals are static and of the chevron type with wear adjustment being taken up either
automatically over a certain range (lower seal) by a wave spring or by manual tightening of a packing nut
(upper seal). The packing nut also contains a fluid compatible lubricant (supplied with pump) which
helps to clean and lubricate the pump rod and upper seal to prolong working life.
The air motor utilises the Binks quick exhaust technology to help reduce the risk of pump stall caused by
air valve sticking from the freezing of moisture contained in the exhausted air. However, in parallel to
this, the operator should endeavour to control the quality of the supplied compressed air to this standard
or better:
Recommended minimum air quality to ISO 8573.1: Class 3.3.2
[Solid particles: 5µm max, water: -20°C pressure dew point, total oil content: 0.1mg/m3 max]
The air motor is furnished with an exhaust muffler to control air exhaust noise emission. An adapter kit is
also available to facilitate connection to a piped exhaust system if required.
GENERAL DESCRIPTION
77-3331 R2.0 (08/2025) 5/20 www.binks.com
EN
Ceramic coated stainless steel
MX20066PU
-CMX/SMX
Stroke length:
66:1
Weight:
Stainless Steel, Ceramic coated Stainless Steel, PTFE, UHMWPE,
FEP, Flurocarbon rubber, Tungsten Carbide.
As above plus carbon steel
Air inlet connection:
Fluid inlet connection:
Fluid outlet connection:
A
B
C
Ram Mount with
Chop-Check
Ram Mount Ram Mount
13.2 l/m [3.5 US
gal/m]
11.4 l/m [3.0 US
gal/m]
5 [127mm]
480 bar [6962 psi] 490 bar [7107 psi]
Displacement per cycle: 200 ml [6.8 US fl oz] 220 ml [7.4 US fl oz] 190 ml [6.4 US fl oz]
MX22060PU
-CMB/SMB
MX19070PU
-CMB/SMB
70:1
7 bar [101.5 psi] 8 bar [116 psi] 7 bar [101.5 psi]
Maximum fluid pressure: 462 bar [6700 psi]
Pump Rod Upper Packing Seal (-PU-) : PTFE & UHMWPE Chevron
Pump Rod Lower Packing Seal (-PU-) : PTFE & UHMWPE Chevron
25
2477 l/m [87.5 SCFM]
3/4 BSPP (f)
3/4 NPT (f)
Output @ 60 cycles/min:
Air flow @ 25 cycles / min 6.9 bar / 100psi:
Maximum Recommended Intermittent Cycle
Rate [cycles / min]:
12.0l/m [3.2 US
gal/m]
-SMX
-SMBWetted parts materials of
construction:
-CMX
-CMB
60:1
Pump Rod Surface Treatment:
-CMX
-CMB
-SMX
-SMB
Carbon Steel (Nitrided Shaft)
79.5 dB(A) Leq
53.5kg [118lbs]
Sound level @ 7 Bar:
Ratio:
Maximum air inlet pressure:
SPECIFICATION
77-3331 R2.0 (08/2025) 6/20 www.binks.com
EN
DIMENSIONS AND MOUNTING DETAILS - MX20066PU-CMX/SMX
SECTION A-A
A
C
B
4x M12x1.75
77-3331 R2.0 (08/2025) 7/20 www.binks.com
EN
DIMENSIONS AND MOUNTING DETAILS
MX22060PU-CMB/SMB & MX19070-CMB/SMB
SECTION A-A
B
C
A
77-3331 R2.0 (08/2025) 8/20 www.binks.com
EN
This product should be flushed with a suitable compatible solvent prior to use.
It is recommended that a suitable filter and regulator unit is fitted into the air line close to the pump to
provide final control of the compressed air to the air motor.
Mount the pump securely and position the pump at a convenient height to allow for maintenance, visual
observation, and periodic inspection.
IF THE SYSTEM IS NOT USED FOR AN EXTENDED PERIOD IT IS RECOMMENDED TO BE FILLED WITH
A LIGHT OIL AFTER CLEANING.
The pump assembly must be connected to a suitable earth ground to ensure that there is no possibility of
electrical static charge build up. A 4 metre grounding cable is supplied with each pump for this purpose -
attached to the pump air motor in the earth location shown in the drawings by use of an M5 screw.
Resistance to earth should be less than 1 Ohm.
Attach suitable pipework or flexible hoses designed to meet the working pressure of the pump assembly
(dependent on pump ratio) to the outlet connection.
Fill the packing cup with a lubricant compatible with the fluid to be pumped. Two small bottles of
lubricant are supplied with the pump - one for use with solvent based fluids and the other for water based
fluids.
Set the pump speed to a slow cycle rate and prime the pump to remove any air before increasing
pressure. Inspect for any air or fluid leaks.
INSTALLATION
77-3331 R2.0 (08/2025) 9/20 www.binks.com
EN
PUMP ASSEMBLY - MX20066PU-CMX/SMX
77-3331 R2.0 (08/2025) 10/20 www.binks.com
EN
1 1
3 3
4 3
5 2
6 1
8 3
13 2
14 3
15 1
16 1
17 2
1
1
M16 WASHER
NAMEPLATE
COVER CLIP
1
Coated stainless steel
pump rod for water
based fluids
1
REMARKSQTY
Hardened steel pump
rod for solvent based
fluids
10
11
12
TIE ROD
MOTOR ROD SPLIT COLLAR
PUMP ROD QD ADAPTER
SPLIT COLLAR RETAINER
HAIR PIN CLIP
RIVET
1
(250mL)1
1
1 (250mL)
1
GROUNDING CABLE
M5 x 12 SOCKET HEAD CAP SCREW
0114-016100
-
-
PARTS LIST - MX20066PU-CMX/SMX
2
7
9
ITEM PART NO. DESCRIPTION
AX260L-7R AIR MOTORAX260L-7R
FX200PU-CMX
FX200PU-SMX
FX200PU-CMX FLUID SECTION
FX200PU-SMX FLUID SECTION
M16 LOCKWASHER
M16 HEX NUT
M5 SPRING WASHER
GUARD
PUMP LUBRICATION - SOLVENT BASED
PUMP LUBRICATION - WATER BASED
20-6832
20-6834
0114-009743
0114-011798
0114-014179
0115-010444
0115-010445
0115-010447
0115-010448
0115-010450
164838
165097
193540
193543
193546
0114-016099
77-3331 R2.0 (08/2025) 11/20 www.binks.com
EN
PUMP ASSEMBLY - MX22060PU-CMB/SMB & MX19070-CMB/SMB
77-3331 R2.0 (08/2025) 12/20 www.binks.com
EN
1
1
3 3
4 3
5 1
6 1
8 3
13 3
14 1
15 2
(MX22060PU-###)
Hardened steel pump
rod for solvent based
fluids
QTY REMARKS
1
Coated stainless steel
pump rod for water
based fluids
1 (250mL)
(MX19070PU-###)
1
1 (250mL)-
M16 WASHER
COVER CLIP
GUARD
PUMP LUBRICATION - SOLVENT BASED
1
1
SPLIT COLLAR RETAINER
HAIR PIN CLIP
1
1
GROUNDING CABLE
M5 x 12 SOCKET HEAD CAP SCREW
TIE ROD
MOTOR ROD SPLIT COLLAR
PUMP ROD QD ADAPTER
165097
193543
193546
0114-016099
0114-016100
PARTS LIST - MX22060PU-CMB/SMB & MX19070-CMB/SMB
1
2
7
9
10
11
12
AX260L-7R AIR MOTOR
AX260L-8R AIR MOTOR
FX220PU-CMB FLUID SECTION
DESCRIPTION
FX190PU-CMB FLUID SECTION
FX220PU-SMB FLUID SECTION
FX190PU-SMB FLUID SECTION
M16 LOCKWASHER
M16 HEX NUT
M5 SPRING WASHER
20-6834
0114-009743
0114-011798
0114-014179
0115-010444
0115-010445
0115-010447
0115-010448
0115-010450
ITEM PART NO.
AX260L-7R
AX260L-8R
FX220PU-CMB
FX190PU-CMB
FX220PU-SMB
FX190PU-SMB
20-6832
PUMP LUBRICATION - WATER BASED-
77-3331 R2.0 (08/2025) 13/20 www.binks.com
EN
Worn or dirty upper ball check.
Worn or dirty lower packings.
Air entering into loose suction side
connections.
Stuck, worn or damaged balls or
seats.
Low material level.
Worn or dirty lower packings.
Contamination trapped between ball
and seat.
Check that all connections are tight.
Replace or clean the parts as
necessary.
Replace or refill material container.
Replace or clean the parts as
necessary.
Clean parts.
Replace poppet assemblies.
Clean or replace the spool and sleeve
assembly as necessary.
Replace piston seal.
Check / replace quick exhaust cups /
diaphragms.
Check compressed air supply.
Clear the blockage.
Replace poppet assemblies.
Replace piston seal.
Check / replace quick exhaust cups /
diaphragms.
Replace or clean upper packings as
necessary.
Replace rod.
Continuous air leak from the exhaust
Material in solvent cup.
Replace or clean the parts as
necessary.
Pump runs, with no output
Pump runs erratically
Worn or dirty lower ball check.
No compressed air.
System is blocked.
Worn poppet assemblies.
Worn or dirty spool and sleeve
assembly.
Worn piston seal.
Quick exhaust valve cup / diaphragm
defective
Worn poppet assemblies.
Worn piston seal.
Quick exhaust valve cup / diaphragm
defective
Worn or dirty upper packings.
Damaged fluid section rod
Pump unable to stall on the down
stroke
Replace or clean the parts as
necessary.
PROBLEM CAUSE SOLUTION
Pump will not start
Pump unable to stall on the up
stroke
Erratic operation of air motor, air
motor stops.
TROUBLESHOOTING
77-3331 R2.0 (08/2025) 14/20 www.binks.com
EN
PREVENTATIVE MAINTENANCE
Check for general air leakage and correct motor operation.
Ensure lubricant is present in the fluid section packing cup. This
should be compatible with the material being pumped.
Confirmation from the supplier of the pumped fluid should be
sought to ensure lubricant compatibility to prevent the risk of
contamination.
Check there is no excessive pumped fluid leaking up into the fluid
section packing cup.
12 to 36 Months (Typically 10
million pump cycles dependent
on air quality and abrasiveness of
the fluid pumped)
Order an air motor seal
kit. See Spare Parts List.
Inspect and replace if required: Main
valve assembly parts.
Order an air motor main
valve repair kit. See Spare
Parts List.
INSPECTION OPERATION
6 Month Test
Replace air piston seal.
Replace motor rod cartridge assembly.
Replace poppet assemblies.
Daily
Perform a pump stall test to ensure correct operation.
Pump should stall in both the upward and downward strokes.
When stalled there should be no continuous escape of air.
77-3331 R2.0 (08/2025) 15/20 www.binks.com
EN
0114-009433
0114-016100
Part No. Description
0114-014871
AGMD-010
0.5L Pump Lubricant (Water Based)
SYNTHETIC GREASE (Kluber ISOFLEX TOPAS NB 52) 50g Tube
Remarks
0114-016099 0.25L Pump Lubricant (Solvent Based)
0.5L Pump Lubricant (Solvent Based)
0.25L Pump Lubricant (Water Based)
ACCESSORIES
192506 Exhaust Tube Adapter - 1½ BSPP - 1½ nominal bore hose
MXA-C13ALM5-H34
Air filter regulator unit with isolator valve and 0.5 metre
pump connection hose
For wall / panel mounting
½ BSPP female inlet
For piped exhaust
77-3331 R2.0 (08/2025) 16/20 www.binks.com
EN
Kit contents are indicated in the respective separate air motor and fluid section service manuals.
For air motor assembly and fluid section assembly, parts listing and servicing information, please see separate air
motor and fluid section service manuals.
250651
Air valve assembly repair kit
Air motor hardware kit
Air motor cylinder seal kit250648
Air motor exhaust seal kit
250649
250650
250699 MX20066PU-CMX/SMX FLUID SECTION SEAL KIT
250645 Air motor seal kit
250732
SPARE PARTS LIST
PART NO. DESCRIPTION
MX22060PU-CMB/SMB FLUID SECTION SEAL KIT
250663 MX19070PU-CMB/SMB FLUID SECTION SEAL KIT
77-3331 R2.0 (08/2025) 17/20 www.binks.com
EN
NOTES
77-3331 R2.0 (08/2025) 18/20 www.binks.com
EN
WARRANTY POLICY
This product is covered by Binks materials and workmanship limited warranty.
The use of any parts or accessories, from a source other than Binks, will void all
warranties. Failure to reasonably follow any maintenance guidance provided, may
invalidate any warranty.
For specific warranty information please contact Binks.
For technical assistance or to locate an authorised distributor, contact one of our
international sales and customer support locations below.
REGION BINKS CONTACT
Americas Tel: 1-888-992-4657
Europe, Africa, Middle East Tel: +44 (0)1202 571 111
India marketingroa@binks.com
China Tel: +8621-3373 0108
Korea Tel: +82313663303
Japan Tel: +81 45 785 6421
Australia Tel: +61 (0) 2 8525 7555
WARRANTY PAGE
77-3331 R2.0 (08/2025) 19/20 www.binks.com
EN
Binks is a global leader in innovative finishing technologies. Binks reserves the right to modify
equipment specifications without prior notice.
Binks®, DeVilbiss®, and Ransburg® are registered trademarks of Binks US, LLC.
© 2025 Binks US, LLC. All rights reserved.
77-3331 R2.0 (08/2025) 20/20 www.binks.com