SB-4-205-R7
®
KB II TWO-QUART PRESSURE CUPS
www.binks.comSB-4-205-R7 (03/2025)
ENADDITIONAL RESOURCES
For additional information or copies of your service manual, please visit us online at:
binks.com/en/library
Or use this QR code with your mobile device:
Obey local or municipal regulations for product recycling and disposal.
KB II TWO-QUART PRESSURE CUPS
www.binks.com SB-4-205-R7 (03/2025)
EN 02. TABLE OF CONTENTS
i / ii
02 CONTENTS
03 SAFETY 1-8
03.1 SAFETY PRECAUTIONS AND HAZARDS �����������������������������������������������������������������������������������������������������������������1
03.2 ADDITIONAL SAFETY INFORMATION ����������������������������������������������������������������������������������������������������������������������8
04 PRODUCT OVERVIEW 9-12
04.1 SPECIFICATIONS �������������������������������������������������������������������������������������������������������������������������������������������������������9
04.2 DESCRIPTION ������������������������������������������������������������������������������������������������������������������������������������������������������������9
04.3 INSTALLATION �����������������������������������������������������������������������������������������������������������������������������������������������������������9
04.4 OPERATION ��������������������������������������������������������������������������������������������������������������������������������������������������������������10
04.5 PREVENTIVE MAINTENANCE ��������������������������������������������������������������������������������������������������������������������������������10
04.6 TROUBLESHOOTING ����������������������������������������������������������������������������������������������������������������������������������������������11
04.7 PARTS LIST ��������������������������������������������������������������������������������������������������������������������������������������������������������������12
05 MANUAL REVISIONS 13
06 WARRANTY POLICY 15
www.binks.comSB-4-205-R7 (03/2025)
EN02. TABLE OF CONTENTS
ii / ii
This page intentionally left blank.
EN 03. SAFETY
www.binks.com SB-4-205-R7 (03/2025)1 / 15
03 SAFETY
03.1 SAFETY PRECAUTIONS
Before the operation, maintenance, or servicing of this
Binks system; fully read and understand all technical
and safety literature for your product. This manual
contains information that is important for you to know and
understand.
This information relates to USER SAFETY and the
PREVENTION OF EQUIPMENT PROBLEMS.
To help you understand this information, we use
recognizable ANSI Z535 and ISO warning boxes and
symbols throughout this manual. Please obey these
safety sections.
WARNING
WARNING!: Indicates a hazardous situation that, if not
avoided, could result in death or severe injury.
CAUTION
Caution!: Indicates a hazardous situation that, if not
avoided, could result in minor or moderate injury, or
equipment damage.
NOTICE
Notice: Indicates information considered important but
not hazard related.
DANGER
DANGER!: Indicates a hazardous situation that, if not
avoided, will result in death or severe injury.
SAFETY
Safety: Indicates a type of safety instruction, or a
separate panel on a safety, where specific safety-
related instructions or procedures are described.
Careful study and continued use of this manual will
provide a better understanding of the equipment functions
and procedures.
This understanding will result in improved operation,
efficiency, and longer, trouble-free service with faster and
easier troubleshooting. If you need the necessary safety
literature for your specific system, contact your local
Binks representative or Binks directly.
WARNING
The hazards shown on the pages that follow can occur
during the normal use of this Binks equipment, but
not all listed hazards will be applicable to your product
model or equipment.
Repairs may only be performed by personnel
authorized by Binks.
WARNING
The user MUST read and be familiar with the Safety
Section in this manual and the safety literature therein
identified.
Only trained personnel can operate this equipment.
All personnel who operate, clean, or maintain this
equipment MUST fully read and understand this
manual! To operate and service the equipment, follow all
WARNINGS and safety requirements.
The user must be aware of and adhere to ALL local
building and fire codes and ordinances, as well as NFPA
33 AND EN 16985 SAFETY STANDARDS, LATEST
EDITION, or applicable country safety standards, before
the installation, operation, or servicing of this equipment.
NOTICE
This manual lists standard specifications and service
procedures. Differences can occur between this
literature and your equipment.
Differences in local or municipal codes, manufacturer
or plant requirements, material delivery requirements,
and more can make variations unpreventable. To
find these differences, compare this manual to your
system installation drawings and other applicable Binks
equipment manuals.
EN03. SAFETY
www.binks.comSB-4-205-R7 (03/2025) 2 / 15
AREAS
Indicate possible
hazard occurrences.
HAZARDS
Indicate possible hazards.
SAFEGUARDS
Prevention of possible hazards.
Spray Areas Fire Hazards
Improper or unsatisfactory
operation and maintenance
procedures will cause a fire
hazard.
If the safety interlocks are
disabled during operation,
protection against accidental
arcing is shut off and can cause
a fire or explosion.
Frequent Power Supply or
Controller shutdown identifies a
problem in the system. For this
occurrence, a correction will be
necessary
Fire extinguishing equipment must be present in the
spray area. Periodically run a test to make sure the
equipment stays usable.
Keep spray areas clean to prevent the build-up of
combustible residues.
Do not smoke in the spray area.
The high voltage supplied to the atomizer must be
turned off before the equipment is cleaned, flushed
or maintained.
Spray booth ventilation must be kept at the rates as
set by NFPA-33, OSHA, country, local, and municipal
codes.
If flammable or combustible solvents are used to
clean the equipment, ventilate the area.
Prevent electrostatic arcing. Maintain spark-safe
work distance between the parts that get coated and
the applicator. A span of one inch for every 10KV of
the output voltage is necessary.
Do an equipment test only in areas free of
combustible material. The test may necessitate the
high voltage to be on, but only as instructed.
Non-factory replacement parts or unauthorized
equipment modifications can cause a fire or injury.
The key switch bypass is used only during setup
operation.
Do no production work with disabled safety
interlocks.
Set up and operate the paint procedure and
equipment under NFPA-33, NEC, OSHA, local,
municipal, country, and European Health and Safety
Norms.
EN 03. SAFETY
www.binks.com SB-4-205-R7 (03/2025)3 / 15
AREAS
Indicate possible
hazard occurrences.
HAZARDS
Indicate possible hazards.
SAFEGUARDS
Prevention of possible hazards.
Spray Areas
General Use and
Maintenance
Explosion Hazard
Improper or unsatisfactory
operation and maintenance
procedures will cause a fire or
explosion hazard.
If the safety interlocks are
disabled during operation,
protection against accidental
arcing is shut off and can cause
a fire or explosion.
Frequent Power Supply or
Controller shutdown identifies a
problem in the system. For this
occurrence, a correction will be
necessary.
Improper or unsatisfactory
operation and maintenance
procedures will cause a fire
hazard.
Personnel must be correctly
trained in the operation and
maintenance of this equipment.
Prevent electrostatic arcing. Maintain spark-safe
work distance between the parts that get coated and
the applicator. A span of one inch for every 10KV of
output voltage is necessary.
Unless specifically approved for use in hazardous
locations, put all electrical equipment outside of
Class I or II, Division 1 or 2 hazardous areas in
accordance with NFPA-33, or outside of Zone 2 or
Zone 22 in accordance with EN standards.
If equipped, set the current overload sensitivity as
described in the related section of the equipment
manual. If incorrectly set, the current overload
sensitivity for protection against accidental arcing is
turned off and can cause a fire or explosion.
Frequent power supply shutdown indicates a
problem in the system, which requires correction.
Always turn off the control panel power before the
system is flushed, cleaned, or servicing the spray
system equipment. Make sure no objects are within
the spark-safe work distance before the high voltage
is turned on.
The control panel must interlock with the ventilation
system and conveyor in accordance with NFPA-33,
EN 50176.
Fire extinguishing equipment must be present in the
spray area. Periodically run a test to make sure the
equipment stays usable. Do an equipment test only
in areas free of combustible material.
Train all personnel in accordance with the
requirements of NFPA-33, EN 60079-0.
Before equipment operation, personnel must read
and understand these instructions and safety
precautions.
Obey appropriate local, municipal, state, and
national codes governing ventilation, fire protection,
operation maintenance, and housekeeping.
Reference OSHA, NFPA-33, EN Norms, and your
insurance company requirements.
EN03. SAFETY
www.binks.comSB-4-205-R7 (03/2025) 4 / 15
AREAS
Indicate possible
hazard occurrences.
HAZARDS
Indicate possible hazards.
SAFEGUARDS
Prevention of possible hazards.
Spray Area High
Voltage Equipment
Electrical Discharge
This equipment contains a
high-voltage device that can
cause an electrostatic induction
on ungrounded objects. This
electrical charge is capable of
igniting coating materials.
Insufficient ground will cause a
spark hazard. A spark can ignite
many coating materials and
cause a fire or explosion.
Operators in the spray area and the parts to be
sprayed must be sufficiently grounded.
All conductive objects inside the spray area must be
grounded.
Hold the parts that get sprayed on conveyors or
hangers that are correctly grounded. The resistance
between the parts and the earth-ground must not be
more than 1 MΩ. Refer to: NFPA-33.
Before the equipment is operated, round all
operators. They cannot wear rubber-soled insulated
shoes. Wear ground straps on wrists or legs for
sufficient ground contact.
Operators must not wear or carry ungrounded metal
objects.
When used, operators must make complete contact
with the applicator handle and electrostatic gun. Use
conductive gloves or gloves with the palm section cut
out.
Operators must not wear grounded footwear.
NOTE: REFER TO NFPA-33 OR SPECIFIC
COUNTRY SAFETY CODES FOR GUIDANCE TO
CORRECTLY GROUND THE OPERATOR.
Except for objects needed for the high-voltage
process, all electrically conductive objects in the
spray area are to be grounded. Supply a grounded
conductive floor in the spray area.
Always turn off the applicator voltage before the
system is flushed, cleaned, or when servicing the
spray system equipment.
Unless specifically approved for use in hazardous
locations, put all electrical equipment outside of
Class I or II, Division 1 or 2 hazardous areas in
accordance with NFPA-33, or outside of Zone 2 or
Zone 22 in accordance with EN standards.
Do not install an applicator into a fluid system if the
solvent supply is ungrounded.
Do not touch an energized applicator electrode.
EN 03. SAFETY
www.binks.com SB-4-205-R7 (03/2025)5 / 15
AREAS
Indicate possible
hazard occurrences.
HAZARDS
Indicate possible hazards.
SAFEGUARDS
Prevention of possible hazards.
Spray Areas
Spray Area and
Equipment Use
Toxic Fluid or Fumes
Toxic fluids or fumes can cause
severe injury or death if splashed
in the eyes or on the skin, or if
inhaled or swallowed.
High-pressure fluid sprayed
from the gun, hose fittings, or
ruptured/damaged components
can pierce the skin.
While this injury can appear as
cut skin, this is a severe injury
that can result in the amputation
of the affected area.
Read the Safety Data Sheet (SDS) for instructions
to know and understand how to handle the specific
hazards of the fluids used, and the effects of long-
term exposure.
During the spray, clean, or servicing of equipment,
or when in the work area, keep the work area fully
ventilated.
Always wear personal protective equipment (PPE)
when in the work area or during equipment operation.
Refer to the Personal Protective Equipment warnings
in this manual.
Store hazardous fluid in approved containers and
refer to local, municipal, state, and national codes
governing the disposal of hazardous fluids.
Do not point or operate the spray gun at the body
part of a person.
Do not put your hand or fingers over the gun fluid
nozzle or fittings in the hose or Proportioner.
Do not try to stop or deflect leaks with your hand,
glove, body, or shop rag.
Do not blowback fluid, as the equipment is not an
air spray system.
Relieve pressure in the supply hoses, Proportioner,
and QuickHeat™ hose before the equipment is
inspected, cleaned, or serviced.
Use the lowest possible pressure to recirculate,
purge, or troubleshoot the equipment.
Examine the hoses, couplings, and fittings every day.
Service or immediately replace parts that leak, are
worn, or are damaged. Replace high-pressure hose
sections. They cannot be recoupled or serviced.
EN03. SAFETY
www.binks.comSB-4-205-R7 (03/2025) 6 / 15
AREAS
Indicate possible
hazard occurrences.
HAZARDS
Indicate possible hazards.
SAFEGUARDS
Prevention of possible hazards.
Equipment
and Fluids
Pressurized
Aluminum Parts
Skin and Clothing Burns
Equipment surfaces and fluids
can become very hot during
operation.
The use of certain solvents and
chemicals can cause equipment
damage and severe personal
injury.
Do not touch hot fluid or equipment during operation.
Do not let clothing touch the equipment during
operation or immediately after the equipment is
stopped.
Let the equipment fully cool before the examination
or servicing of the component.
Do not use 1,1,1-trichloroethane, methylene
chloride or other halogenated hydrocarbon solvents
or fluids that contain such solvents.
These solvents can cause a severe chemical
reaction and equipment rupture that results in
equipment and property damage, serious bodily
injury, or death.
EN 03. SAFETY
www.binks.com SB-4-205-R7 (03/2025)7 / 15
AREAS
Indicate possible
hazard occurrences.
HAZARDS
Indicate possible hazards.
SAFEGUARDS
Prevention of possible hazards.
Spray Areas Do Not Touch
The effect of paint flow rates
and formulations on the quality
of atomization can cause the
turbines to rotate at high speeds.
Do not use a rag or gloved hand against the bell
edge to stop or slow down a bell during rotation.
Do not try to clean the bell edge during rotation.
EN03. SAFETY
www.binks.comSB-4-205-R7 (03/2025) 8 / 15
If the operation of this equipment, sensors, switches, or other ancillary equipment occurs in the presence of flammable
gases and vapors, connect this equipment through intrinsic-safe or Zener barriers. Classify them as a ‘simple apparatus’
or approve them for use in these areas.
03.2 ADDITIONAL SAFETY INFORMATION
Observe all local or municipal safety measures and wear approved protective equipment when servicing this equipment.
Clean all spilled chemicals and materials and do all work in a clean and organized environment to prevent personal
injury and equipment damage.
NOTICE
During the initial commission of the equipment and at periodic times throughout equipment life, visually examine all
fluid fittings for leaks.
Periodically, it is necessary to visually examine all pieces of this equipment for signs of noticeable degradation due to
chemicals or other conditions in the equipment’s environment.
CAUTION
Only operate the equipment after you have read this section.
DANGER
To prevent injury or electrocution while the system is under power, do not contact, disconnect, or manipulate electrical
connections or devices. The main disconnect on the right side of the controller can be locked out. Follow the proper
Lockout–Tagout (LOTO) procedures for internal controller electrical work.
Only qualified electrical personnel can perform the work if diagnosis and troubleshooting are not possible during
working conditions.
WARNING
To prevent possible chemical spillage when personnel are not on site, air and fluid supplies for the equipment must be
disabled when the equipment idles for an extended period, such as an end-of-day shutdown.
SAFETY
Obey local or municipal regulations that require installed fire suppression for equipment operation.
EN 04. PRODUCT OVERVIEW
www.binks.com SB-4-205-R7 (03/2025) 9 / 15
04 PRODUCT OVERVIEW
KB II TWO-QUART PRESSURE CUPS
KB-555 Aluminum,
KB-545-SS Stainless Steel (Obsolete)
GOVERNMENT NSN NO. 4940-01-106-1415 = KB-555 CUP
04.1 SPECIFICATIONS
Maximum regulated cup pressure
50 psi (3.5 bar) (fluid pressure)
Maximum air inlet pressure (to inlet on handle)
125 psi (8.5 bar)
Hose Connections
Air - 1/4 NPS/BSPP (M)
Fluid - 3/8 NPS/BSPP (M)
Model Nos. KB-555 KB-545-SS
Height 7-3/16 7-3/16
Weight 3 lb. 14 oz. 4 lb. 5 oz.
Fluid Capacity 77 oz. Maximum 77 oz. Maximum
Wetted Parts KB-555 KB-545-SS
Cup Aluminum 304 Electro
Polished S.S.
Lid Gasket Sarlink Sarlink
Check Valve Assy. Nylon Nylon
Fluid Tube Assy. Aluminum 304 S.S.
Passivated
Fluid Tube Nut Nickel Plated
Brass
304 S.S.
Passivated
Cup Lid Aluminum Electroless
Nickel Plated
Aluminum
Bleed Down Valve Nickel Plated
Brass
304 S.S.
Passivated
KK-5051 Liners Polyethylene Polyethylene
04.2 DESCRIPTION
All KB-II style cups are pressure regulated
and have a 2.4 quart (77 oz.) capacity. They are designed
to be attached to any manual spray gun with air and
material hose. The cup may be carried in one hand
using the comfortable hand grip or left on the floor while
spraying. The KB-II's wide diameter and low profile
provides a low center of gravity which increases stability
and resists tipping. Models KB-555 and KB-545-SS
include a 0-30 psi gauge. KB II cups are supplied with
KK-5051 disposable cup liners (5 each) to reduce clean
up time and cleaning solvent.
Pressure cups provide a greater degree of control over
atomization air and material pressure than obtainable
through use of suction feed equipment. Pressure
cups also enable user to apply heavy or more viscous
materials in small amounts where a 2 quart capacity is
sufficient for the job.
04.3 INSTALLATION
WARNING
Risk of injury. Cup is under pressure. Disconnect cup
assembly from air supply before installing or removing
lid assembly from cup for filling or cleaning.
1. � Connect fluid hose (A) to fluid inlet of gun and outlet of
cup (1) as shown. See Figure 1.
2. � Connect atomization air hose (B) to air inlet of gun and
outlet of cup (2) as shown. See Figure 1.
3. � Connect air supply hose (C) to inlet coupling (3) on
cup handle. See Figure 1.
NOTICE
Order hoses separately.
C
CleanAir
Filter
A
B
2
1
3
Air Inlet
Figure 1
EN04. PRODUCT OVERVIEW
www.binks.comSB-4-205-R7 (03/2025) 10 / 15
04.4 OPERATION
WARNING
Risk of injury or equipment damage. Air pressure to the
cup must never exceed 50 psi, (3.5 bar).
Mix and prepare the material to be sprayed according to
manufacturer's instructions. Strain material through a 60
to 90 mesh screen or equivalent before spraying. Place
KK-5051 disposable liner into cup. Refer to instructions
provided with KK-5051.
DESCRIPTION OF CONTROLS
(Refer to Figure 2)
Regulator Assembly (15)
Controls pressure on material in cup.
Pressure Bleed Down Valve (6)
Allows air to be bled from cup
To reduce pressure in cup, turn knob of regulator
assembly counterclockwise. Bleed off excess air
by momentarily turning pressure relief valve (6)
counterclockwise. Readjust pressure by turning knob of
regulator (24) assembly clockwise. Turning regulator all
the way out shuts off air supply to the cup.
NOTICE
Turn pressure bleed valve (6) counterclockwise to
vent air from the cup; it is important to do this before
removing lid.
1. � Place lid on cup. Grasp lid handle and push down
with one hand and tighten retaining ring (1) with other
hand.
2. � Turn regulator knob (24) out (counterclockwise) until
no spring pressure is felt.
3. � Close pressure bleed valve (6) by turning it in all the
way clockwise.
4. � Set air supply pressure at approximately 50-60 pounds
at regulator.
5. � Set material pressure at 10 pounds by turning in
regulator knob and reading the gauge. Make sure
fluid adjusting screw on spray gun is open (turned out
counterclockwise until first thread shows).
6. � Test for amount of paint in relation to the speed at
which you want to spray. If too much paint is coming
out or atomized particle size of paint is too large, follow
one of the procedures below.
A. � Turn regulator knob counterclockwise until
gauge shows lower pressure. Bleed off
excessive air in cup by turning pressure bleed
valve (6) counterclockwise.
B. � Raise air pressure at regulator until well
defined atomized pattern of paint is evident.
This increases air pressure to spray gun while
maintaining same pressure in the cup.
04.5 PREVENTIVE MAINTENANCE
CAUTION
Always relieve pressure in cup before removing lid by
turning bleed valve out.
NOTICE
Do not unthread the pressure bleed valve (6) all the
way, as it may fall out and be lost.
CLEANING
CAUTION
Do not wash the lid assembly in a gun washer.
The safety valve, gauge and regulator contain parts
that will be damaged. The cup only can be washed
in a gun washer.
Use of the KK-5051 disposable cup liner will significantly
reduce cleaning time and sol-vent. Another accessory
item, KK-5052 Adapter and Hose Kit, can also be used in
conjunction with the Solvent Saver™ to
save further time and solvent cleaning the fluid passages
of the tube, hose, and spray gun.
Grasp lid handle and push down with one hand and turn
the retaining ring (1) counterclockwise with the other
hand. Pour out any remaining material and add a suitable
solvent. Close cup lid as explained in OPERATION
section. Spray until clean solvent appears. Cup and
gun material passages should now be clean. Empty any
remaining solvent from cup. Wipe cup with a solvent
soaked cloth.
CHECK VALVE
If contaminated, carefuly remove check valve (12) from
lid. Soak in suitable solvent. If damaged, replace. Do not
torque to more than 10 in. lbs.
EN 04. PRODUCT OVERVIEW
www.binks.com SB-4-205-R7 (03/2025) 11 / 15
SAFETY VALVE, REGULATOR, PRESSURE GAUGE
WARNING
The safety valve limits the maximum air pressure. If the
safety valve does not work properly, over pressurization
may occur and cause the cup to rupture or explode.
Occasionally pull the ring on the safety valve and make
sure it operates freely. If the valve is stuck or does
not operate smoothly, it must be replaced with a valve
having the same rating. Never attempt to adjust or
disassemble the safety valve.
The safety valve (14) is factory set at approximately
55 lbs. Never disassemble. If damaged, replace. Never
submerge in solvents.
REGULATOR DISASSEMBLY
1. � Pull the knob on the bonnet outward to unlock
regulator knob.
2. � Turn the knob counterclockwise to stop.
3. � Remove bonnet (24) by turning it counterclockwise.
Use pliers if necessary.
4. � Remove adjusting screw and nut, regulating spring,
slip ring and diaphragm.
5. � Use a wide blade screw driver and turn valve seat (18)
counterclockwise to remove along with o-ring.
6. � Carefully remove valve (17) and valve spring (16).
REGULATOR REASSEMBLY
1. � Place valve spring (16) into center hole of cast
housing. Place valve (17) on the spring (16).
2. � Use a wide blade screw driver and tighten valve seat
and o-ring assembly (18) to 4-6 in. lbs. torque.
3. � Place diaphragm (19) on the valve seat. Diaphragm
tube must slide freely through valve seat after valve
seat is torqued into the body.
4. � Place slip ring (20) on inside shoulder of bonnet (24).
5. � Place adjusting screw (23), nut (22) and regulating
spring (21) into bonnet (24).
6. � Tighten bonnet assembly (24) to 65-75 in. lbs. torque.
04.6 TROUBLESHOOTING
PROBLEM CAUSE CORRECTION
Excess pressure in cup. Gauge (8) registering incorrectly Replace.
Safety valve (14) setting too high. Replace.
Valve spring (16) broken or distorted. Replace.
Diaphragm (19) damaged. Replace.
Leak at regulator valve (17 and 18). Replace.
Insufficient pressure in cup. Safety valve (14) leaking. Replace.
Check valve (12) stuck shut. Clean or replace.
Gauge (8) registering incorrectly. Replace.
Leak at cup lid (11) threads. Tighten cup or replace gasket (9) or slip ring (2).
EN04. PRODUCT OVERVIEW
www.binks.comSB-4-205-R7 (03/2025) 12 / 15
• �These parts are included in the Regulator Kit KB-428-1.
# �Recommended Spare Parts and KB-428-1 Regulator Kit.
* �A secondary handle (3) has been provided with each cup. May be used for Belt Hanging.
+ �These parts are included in Ref. No. 267, Fluid Tube Kit.
✖ �Apply thread sealant (i.e. Loctite #242 medium strength blue or equal) unto threads.
04.7 PARTS LIST
REF.
NO. PART NO. DESCRIPTION
IND.
PARTS
REQ.
1 KB-64 Retaining Ring 1
2 # KB-81-K5 Slip Ring (Kit of 5) 1
3* KB-74 Handle - Secondary 1
4 --- Nut 5/16-18 (purchase locally) 1
5 P-MB-51 Adapter 2
6 # KB-66 Pressure Bleed Valve (For KB-555) 1
--- Pressure Bleed Valve (For KB-545-SS) 1
7 KB-70 Lid w/handle (For KB-555) 1
--- Lid w/handle (For KB-545-SS) 1
8 GA-355 Pressure Gauge 0-30 psi 1
9 # KB-80-K5 Gasket (Kit of 5) 1
10+ MBD-11-K5 Locknut (For KB-555, Kit of 5) 1
--- Locknut (For KB-545-SS) 1
11 KB-422 2 qt. cup (For KB-555) 1
--- 2 qt. cup (For KB-545-SS) 1
12 KB-432-K3 Check Valve (Kit of 3) 1
13# KB-85-K5 Gasket (Kit of 5) 1
14 TIA-4355 Safety Valve 1
15 KB-428-1 Regulator Kit 1
16• --- Valve Spring 1
17• --- Valve, PTFE 1
18• --- Valve Seat and O-Ring Assembly 1
19• --- Diaphragm, PTFE protected 1
20• --- Slip Ring 1
21• --- Regulator Spring 1
22• --- Nut 1
23• --- Adjusting Screw 1
24• --- Bonnet 1
25+ KB-60-K6 Gasket (Kit of 6) 1
27 KK-4997 Fluid Tube Kit - (Aluminum For KB-555) 1
KK-4996 Fluid Tube Kit - (Stainless Steel for KB-545-SS) 1
6✖5
3
2
1
✖5
4
20
21
1716
19
27
25
26
24
15 18
Figure 2
22
23
1312
14
9
8
7
10 27
11
EN 05. MANUAL REVISIONS
www.binks.com SB-4-205-R7 (03/2025) 13 / 15
MANUAL CHANGE SUMMARY
Date Description Version
03/01/2025 Rebranded to Binks R7
EN05. MANUAL REVISIONS
www.binks.comSB-4-205-R7 (03/2025) 14 / 15
This page intentionally left blank.
EN 06. WARRANTY
WARRANTY POLICY
This product is covered by Binks’ materials and workmanship limited warranty.
The use of parts or accessories from sources other than Binks will void all warranties. Failure to follow reasonable
maintenance guidance provided can invalidate the warranty.
For specific warranty information, please contact Binks.
For technical assistance or to locate an authorized distributor, contact one of our international sales
and customer support locations listed below.
www.binks.com SB-4-205-R7 (03/2025) 15 / 15
REGION BINKS CONTACT
Americas Tel: 1-800-992-4657
Europe, Africa, Middle East Tel: +4401202571111
India marketingroa@binks.com
China Tel: +862133730108
Korea Tel: +82313663303
Japan Tel: +81457856421
Australia Tel: +61085257555
WARRANTY PAGE
EN
Binks is a global leader in innovative finishing technologies.
Binks reserves the right to modify equipment specifications without prior notice.
Binks®, DeVilbiss® and Ransburg® are registered trademarks of Binks US, LLC.
©2025 Binks US, LLC. All rights reserved.
SAFETY
SAFETY PRECAUTIONS
ADDITIONAL SAFETY INFORMATION