- Insulation Hose Repair Procedure SI-347699 EN [ English ]
- Insulation Hose Repair Procedure SI-347699 CH [ Chinese ]
SI-347699
IntelliSpray QuickHeat™ Hose
®
TEAR RESISTANT HOSE
INSULATION REPAIR KIT (347698)
INSTRUCTIONS
www.binks.comSI-347699 R3 (06/2025)
ENADDITIONAL RESOURCES
For additional information or copies of your service manual, please visit us online at:
binks.com/en/library
Or use this QR code with your mobile device:
QUICK HEAT HOSE
Obey local or municipal regulations for product recycling and disposal.
https://carlisleft.com/en/product/is40-proportioner/
www.binks.com SI-347699 R3 (06/2025)
EN INTRODUCTION
i / iv
ABOUT THIS MANUAL
ITS PURPOSE
The purpose of this manual is to help you get the most
value from your Binks IntelliSpray™ system. It can
help you to determine how to install, operate, maintain,
and repair your equipment. It provides information and
procedures for routine maintenance and servicing and
offers diagnostic and repair procedures to follow when
trouble occurs.
ITS CONTENTS
This manual is divided into Chapters, each of which is
divided into consecutively numbered Sections.
Chapters will contain text, images, tables, or a
combination of them.
Pages with images will have paragraphs and sentences
with callout numbers that refer to their respective images,
steps, and parts.
Procedures, once described in the text, are not normally
repeated. When it is necessary to refer to another Chapter
or Section, the reference will be given as Chapter and
Section number. Cross references given without the use
of the word Chapter apply to Sections or paragraphs in
the current Chapter.
Chapter 02. Table of Contents.
Chapter 03. Safety - Safety, hazard, and warning rules.
Chapter 04. Isocyanate Information - Information about
Isocyanate chemicals.
Chapter 05. Insulation Replacement - Procedures for the
removal and installation of QuickHeat Hose insulation.
Chapter 06. Manual Change Summary - The revisions and
changes made to this manual.
Chapter 07. Warranty - Your equipment’s warranty.
WHO SHOULD USE THIS GUIDE
This guide is intended for users with different levels of
knowledge and experience with this system:
Installers: The person(s) who will locate and install this
equipment.
Users: The person(s) who will learn how to operate this
equipment.
Servicers: The person(s) who will service and maintain
this equipment.
This guide assumes all persons who will install, use,
operate, and service this equipment have some
knowledge of the product and its operating system.
MANUAL DISCLAIMER
All current and applicable certifications shown in this
manual confirm Binks' adherence to the strict standards
met to obtain the required regulatory compliances.
This manual was prepared with the most accurate
information current at the time of publishing. Binks does
not accept responsibility for errors in, or omissions from,
the information contained herein.
Please get in touch with your distributor or Binks
Customer Service for additional service information and
assistance.
www.binks.comSI-347699 R3 (06/2025)
ENINTRODUCTION
ii / iv
RELATED MANUALS & PUBLICATIONS
Part Number Description
341164 QuickHeat Hose Manual
www.binks.com SI-347699 R3 (06/2025)
EN 02. TABLE OF CONTENTS
iii / iv
02. CONTENTS
03 SAFETY 3
03.1 SAFETY PRECAUTIONS....................................................................................................................................3
03.2 ADDITIONAL SAFETY INFORMATION.............................................................................................................10
04. IMPORTANT ISOCYANATE INFORMATION 11
04.1 GENERAL HANDLING GUIDELINES................................................................................................................11
04.2 MATERIAL SELF IGNITION...............................................................................................................................12
04.3 KEEP COMPONENTS A & B SEPARATE..........................................................................................................12
04.4 EXPOSURE TO MOISTURE..............................................................................................................................12
04.5 FOAM RESINS WITH 245 FA BLOWING AGENTS...........................................................................................12
04.6 CHANGING MATERIALS...................................................................................................................................12
04.7 ELECTRICAL GROUND....................................................................................................................................12
05. INSULATION REPLACEMENT 13
05.1 HOSE DISASSEMBLY.......................................................................................................................................13
05.2 HOSE ASSEMBLY.............................................................................................................................................14
06. MANUAL REVISIONS 17
07. WARRANTY 19
www.binks.comSI-347699 R3 (06/2025)
EN02. TABLE OF CONTENTS
iv / iv
This page intentionally left blank.
EN 03. SAFETY
www.binks.com SI-347699 R3 (06/2025) 1 / 17
03 SAFETY
03.1 SAFETY PRECAUTIONS
Before the operation, maintenance, or servicing of this
Binks system; fully read and understand all technical
and safety literature for your product. This manual
contains information that is important for you to know and
understand.
This information relates to USER SAFETY and the
PREVENTION OF EQUIPMENT PROBLEMS.
To help you understand this information, we use
recognizable ANSI Z535 and ISO warning boxes and
symbols throughout this manual. Please obey these
safety sections.
Careful study and continued use of this manual will
provide a better understanding of the equipment functions
and procedures.
This understanding will result in improved operation,
efficiency, and longer, trouble-free service with faster and
easier troubleshooting. If you need the necessary safety
literature for your specific system, contact your local Binks
representative or Binks directly.
WARNING
WARNING!: Indicates a hazardous situation that, if not
avoided, could result in death or severe injury.
CAUTION
Caution!: Indicates a hazardous situation that, if not
avoided, could result in minor or moderate injury, or
equipment damage.
NOTICE
Notice: Indicates information considered important but
not hazard related.
DANGER
DANGER!: Indicates a hazardous situation that, if not
avoided, will result in death or severe injury.
SAFETY
Safety: Indicates a type of safety instruction, or a
separate panel on a safety placard, where specific
safety-related instructions or procedures are described.
WARNING
The hazards shown on the pages that follow can occur
during the normal use of this Binks equipment, but
not all listed hazards will be applicable to your product
model or equipment.
Repairs may only be performed by personnel
authorized by Binks.
WARNING
The user MUST read and be familiar with the Safety
Section in this manual and the safety literature therein
identified.
Only trained personnel can operate this equipment.
All personnel who operate, clean, or maintain this
equipment MUST fully read and understand this
manual! To operate and service the equipment, follow all
WARNINGS and safety requirements.
The user must be aware of and adhere to ALL local
building and fire codes and ordinances, as well as NFPA
33 AND EN 16985 SAFETY STANDARDS, LATEST
EDITION, or applicable country safety standards, before
the installation, operation, or servicing of this equipment.
NOTICE
This manual lists standard specifications and service
procedures. Differences can occur between this
literature and your equipment.
Differences in local or municipal codes, manufacturer
or plant requirements, material delivery requirements,
and more can make variations unpreventable. To
find these differences, compare this manual to your
system installation drawings and other applicable Binks
equipment manuals.
EN04. SAFETY
www.binks.comSI-347699 R3 (06/2025) 2 / 17
AREAS
Indicate possible
hazard occurrences.
HAZARDS
Indicate possible hazards.
SAFEGUARDS
Prevention of possible hazards.
Spray Areas Fire Hazards
Improper or unsatisfactory
operation and maintenance
procedures will cause a fire
hazard.
If the safety interlocks are
disabled during operation,
protection against accidental
arcing is shut off and can cause
a fire or explosion.
Frequent Power Supply or
Controller shutdown identifies a
problem in the system. For this
occurrence, a correction will be
necessary
Fire extinguishing equipment must be present in the
spray area. Periodically run a test to make sure the
equipment stays usable.
Keep spray areas clean to prevent the build-up of
combustible residues.
Do not smoke in the spray area.
The high voltage supplied to the atomizer must be
turned off before the equipment is cleaned, flushed
or maintained.
Spray booth ventilation must be kept at the rates as
set by NFPA-33, OSHA, country, local, and municipal
codes.
If flammable or combustible solvents are used to
clean the equipment, ventilate the area.
Prevent electrostatic arcing. Maintain spark-safe
work distance between the parts that get coated and
the applicator. A span of one inch for every 10KV of
the output voltage is necessary.
Do an equipment test only in areas free of
combustible material. The test may necessitate the
high voltage to be on, but only as instructed.
Non-factory replacement parts or unauthorized
equipment modifications can cause a fire or injury.
The key switch bypass is used only during setup
operation.
Do no production work with disabled safety
interlocks.
Set up and operate the paint procedure and
equipment under NFPA-33, NEC, OSHA, local,
municipal, country, and European Health and Safety
Norms.
EN 03. SAFETY
www.binks.com SI-347699 R3 (06/2025) 3 / 17
AREAS
Indicate possible
hazard occurrences.
HAZARDS
Indicate possible hazards.
SAFEGUARDS
Prevention of possible hazards.
Spray Areas
General Use and
Maintenance
Explosion Hazard
Improper or unsatisfactory
operation and maintenance
procedures will cause a fire or
explosion hazard.
If the safety interlocks are
disabled during operation,
protection against accidental
arcing is shut off and can cause
a fire or explosion.
Frequent Power Supply or
Controller shutdown identifies a
problem in the system. For this
occurrence, a correction will be
necessary.
Improper or unsatisfactory
operation and maintenance
procedures will cause a fire
hazard.
Personnel must be correctly
trained in the operation and
maintenance of this equipment.
Prevent electrostatic arcing. Maintain spark-safe
work distance between the parts that get coated and
the applicator. A span of one inch for every 10KV of
output voltage is necessary.
Unless specifically approved for use in hazardous
locations, put all electrical equipment outside of
Class I or II, Division 1 or 2 hazardous areas in
accordance with NFPA-33, or outside of Zone 2 or
Zone 22 in accordance with EN standards.
If equipped, set the current overload sensitivity as
described in the related section of the equipment
manual. If incorrectly set, the current overload
sensitivity for protection against accidental arcing is
turned off and can cause a fire or explosion.
Frequent power supply shutdown indicates a
problem in the system, which requires correction.
Always turn off the control panel power before the
system is flushed, cleaned, or servicing the spray
system equipment. Make sure no objects are within
the spark-safe work distance before the high voltage
is turned on.
The control panel must interlock with the ventilation
system and conveyor in accordance with NFPA-33,
EN 50176.
Fire extinguishing equipment must be present in the
spray area. Periodically run a test to make sure the
equipment stays usable. Do an equipment test only
in areas free of combustible material.
Train all personnel in accordance with the
requirements of NFPA-33, EN 60079-0.
Before equipment operation, personnel must read
and understand these instructions and safety
precautions.
Obey appropriate local, municipal, state, and
national codes governing ventilation, fire protection,
operation maintenance, and housekeeping.
Reference OSHA, NFPA-33, EN Norms, and your
insurance company requirements.
EN04. SAFETY
www.binks.comSI-347699 R3 (06/2025) 4 / 17
AREAS
Indicate possible
hazard occurrences.
HAZARDS
Indicate possible hazards.
SAFEGUARDS
Prevention of possible hazards.
Spray Area High
Voltage Equipment
Electrical Discharge
This equipment contains a
high-voltage device that can
cause an electrostatic induction
on ungrounded objects. This
electrical charge is capable of
igniting coating materials.
Insufficient ground will cause a
spark hazard. A spark can ignite
many coating materials and
cause a fire or explosion.
Operators in the spray area and the parts to be
sprayed must be sufficiently grounded.
All conductive objects inside the spray area must be
grounded.
Hold the parts that get sprayed on conveyors or
hangers that are correctly grounded. The resistance
between the parts and the earth-ground must not be
more than 1 MΩ. Refer to: NFPA-33.
Before the equipment is operated, ground all
operators. They cannot wear rubber-soled insulated
shoes. Wear ground straps on wrists or legs for
sufficient ground contact.
Operators must not wear or carry ungrounded metal
objects.
When used, operators must make complete contact
with the applicator handle and electrostatic gun. Use
conductive gloves or gloves with the palm section cut
out.
Operators must wear grounded footwear.
NOTE: REFER TO NFPA-33 OR SPECIFIC
COUNTRY SAFETY CODES FOR GUIDANCE TO
CORRECTLY GROUND THE OPERATOR.
Except for objects needed for the high-voltage
process, all electrically conductive objects in the
spray area are to be grounded. Supply a grounded
conductive floor in the spray area.
Always turn off the applicator voltage before the
system is flushed, cleaned, or when servicing the
spray system equipment.
Unless specifically approved for use in hazardous
locations, put all electrical equipment outside of
Class I or II, Division 1 or 2 hazardous areas in
accordance with NFPA-33, or outside of Zone 2 or
Zone 22 in accordance with EN standards.
Do not install an applicator into a fluid system if the
solvent supply is ungrounded.
Do not touch an energized applicator electrode.
EN 03. SAFETY
www.binks.com SI-347699 R3 (06/2025) 5 / 17
AREAS
Indicate possible
hazard occurrences.
HAZARDS
Indicate possible hazards.
SAFEGUARDS
Prevention of possible hazards.
Spray Areas
Spray Area and
Equipment Use
Toxic Fluid or Fumes
Toxic fluids or fumes can cause
severe injury or death if splashed
in the eyes or on the skin, or if
inhaled or swallowed.
High-pressure fluid sprayed
from the gun, hose fittings, or
ruptured/damaged components
can pierce the skin.
While this injury can appear as
cut skin, this is a severe injury
that can result in the amputation
of the affected area.
Read the Safety Data Sheet (SDS) for instructions
to know and understand how to handle the specific
hazards of the fluids used, and the effects of long-
term exposure.
During the spray, clean, or servicing of equipment,
or when in the work area, keep the work area fully
ventilated.
Always wear personal protective equipment (PPE)
when in the work area or during equipment operation.
Refer to the Personal Protective Equipment warnings
in this manual.
Store hazardous fluid in approved containers and
refer to local, municipal, state, and national codes
governing the disposal of hazardous fluids.
Do not point or operate the spray gun at the body
part of a person.
Do not put your hand or fingers over the gun fluid
nozzle or fittings in the hose or Proportioner.
Do not try to stop or deflect leaks with your hand,
glove, body, or shop rag.
Do not blowback fluid, as the equipment is not an
air spray system.
Relieve pressure in the supply hoses, Proportioner,
and QuickHeat™ hose before the equipment is
inspected, cleaned, or serviced.
Use the lowest possible pressure to recirculate,
purge, or troubleshoot the equipment.
Examine the hoses, couplings, and fittings every day.
Service or immediately replace parts that leak, are
worn, or are damaged. Replace high-pressure hose
sections. They cannot be recoupled or serviced.
EN04. SAFETY
www.binks.comSI-347699 R3 (06/2025) 6 / 17
AREAS
Indicate possible
hazard occurrences.
HAZARDS
Indicate possible hazards.
SAFEGUARDS
Prevention of possible hazards.
Equipment
and Fluids
Pressurized
Aluminum Parts
Skin and Clothing Burns
Equipment surfaces and fluids
can become very hot during
operation.
The use of certain solvents and
chemicals can cause equipment
damage and severe personal
injury.
Do not touch hot fluid or equipment during operation.
Do not let clothing touch the equipment during
operation or immediately after the equipment is
stopped.
Let the equipment fully cool before the examination
or servicing of the component.
Do not use 1,1,1-trichloroethane, methylene
chloride or other halogenated hydrocarbon solvents
or fluids that contain such solvents.
These solvents can cause a severe chemical
reaction and equipment rupture that results in
equipment and property damage, serious bodily
injury, or death.
EN 03. SAFETY
www.binks.com SI-347699 R3 (06/2025) 7 / 17
AREAS
Indicate possible
hazard occurrences.
HAZARDS
Indicate possible hazards.
SAFEGUARDS
Prevention of possible hazards.
Spray Areas Do Not Touch
The effect of paint flow rates
and formulations on the quality
of atomization can cause the
turbines to rotate at high speeds.
Do not use a rag or gloved hand against the bell
edge to stop or slow down a bell during rotation.
Do not try to clean the bell edge during rotation.
EN04. SAFETY
www.binks.comSI-347699 R3 (06/2025) 8 / 17
If the operation of this equipment, sensors, switches, or other ancillary equipment occurs in the presence of flammable
gases and vapors, connect this equipment through intrinsic-safe or Zener barriers. Classify them as a ‘simple apparatus’
or approve them for use in these areas.
03.2 ADDITIONAL SAFETY INFORMATION
The IntelliSpray™ has an emergency stop (E-Stop) pushbutton on the main operator panel. During an emergency, all
operations for the IntelliSpray will halt when the E-Stop is engaged. The operator must disengage the E-Stop and reset
the system to recover from this state.
Observe all local or municipal safety measures and wear approved protective equipment when servicing this equipment.
Clean all spilled chemicals and materials and do all work in a clean and organized environment to prevent personal
injury and equipment damage.
NOTICE
During the initial commission of the equipment and at periodic times throughout equipment life, visually examine all
fluid fittings for leaks.
Periodically, it is necessary to visually examine all pieces of this equipment for signs of noticeable degradation due to
chemicals or other conditions in the equipment’s environment.
CAUTION
Only operate the equipment after you have read this section.
DANGER
To prevent injury or electrocution while the system is under power, do not contact, disconnect, or manipulate electrical
connections or devices. The main disconnect on the right side of the controller can be locked out. Follow the proper
Lockout–Tagout (LOTO) procedures for internal controller electrical work.
Only qualified electrical personnel can perform the work if diagnosis and troubleshooting are not possible during
working conditions.
WARNING
To prevent possible chemical spillage when personnel are not on site, air and fluid supplies for the equipment must be
disabled when the equipment idles for an extended period, such as an end-of-day shutdown.
SAFETY
Obey local or municipal regulations that require installed fire suppression for equipment operation.
www.binks.com SI-347699 R3 (06/2025) 9 / 17 www.binks.comSI-347699 R3 (06/2025) PB / 17
EN EN 04. ISOCYANATE INFORMATION
04. IMPORTANT ISOCYANATE
INFORMATION
04.1 GENERAL HANDLING GUIDELINES
Isocyanates (ISO) are catalysts used in two component
materials.
Fluids with isocyanates that are sprayed or dispensed
creates potentially harmful mists, vapors, and atomized
particulates. Workers exposed to isocyanates can
develop a range of short and long-term health problems.
Read and understand the fluid manufacturer’s warnings
and Safety Data Sheet (SDS) for specific hazards and
precautions related to isocyanates.
• Use of isocyanates involves potentially hazardous
procedures. Do not spray with this equipment
unless you are trained, qualified, and have read and
understood the information in this manual and in the
fluid manufacturer’s application instructions and SDS.
• Use of incorrectly maintained or adjusted equipment
may result in unsatisfactory cured material which
can off-gas and make offensive odors. Refer to the
instruction in the manual to correctly maintain and
operate the equipment.
• To prevent inhalation of isocyanate mists, vapors
and atomized particulates, everyone in the work
area must wear applicable respiratory protection.
Always wear a correctly fitted respirator that includes
a supplied-air respirator. Refer to the instructions in
the fluid manufacturer’s SDS for correct work area
airflow.
• Avoid all skin contact with isocyanates. Everyone in
the work area must wear chemically impermeable
gloves, protective clothing, and foot cover
recommended by the fluid manufacturer and local
regulatory authorities. Follow all fluid manufacturer
recommendations, to include the discard of
contaminated clothing. Do not eat or drink after
equipment use until hands and face have been
washed.
• Hazard from exposure to isocyanates continues after
spray use. Anyone without correct personal protective
equipment must stay out of the work area during and
after the application, and for the time period specified
by the fluid manufacturer. This time period is usually a
minimum of 24 hours.
• Warn others who may enter work area of hazard
from exposure to isocyanates. Follow the
recommendations of the fluid manufacturer and local
regulatory authority.
• It is recommended to post a sign outside the work as
the one shown below:
WARNING
DO NOT ENTER UNTIL AFTER:
DO NOT ENTER DURING SPRAY
FOAM APPLICATION OR FOR ─
HOURS AFTER APPLICATION IS
COMPLETE
TOXIC FUME HAZARD
DATE: TIME:
www.binks.com SI-347699 R3 (06/2025) PB / 17 www.binks.comSI-347699 R3 (06/2025) 10 / 17
EN EN04. ISOCYANATE INFORMATION
04.2 MATERIAL SELF IGNITION
Some materials may become self-igniting if applied too
thick. Read material manufacturer's warnings and Safety
Data Sheet
04.3 KEEP COMPONENTS A & B SEPARATE
Prevent cross contamination of A and B materials. Cured
material in fluid lines and passages can cause serious
personal injury or equipment damage.
Never interchange the wetted parts of components A and
B.
Never use solvent on one side that is contaminated with
fluid from the other side.
04.4 EXPOSURE TO MOISTURE
ISO will start to cure and form small, hard, abrasive
crystals when exposed to moisture and humidity.
These crystals become suspended in the fluid and can
cause equipment damage. Over time, a film will form on
the surface and the ISO will get thicker with increased
viscosity.
Take the following steps to prevent damage to spray gun
components due to cured ISO:
• A sealed container with a desiccant dryer in the vent,
or a nitrogen atmosphere in the empty head space of
the container must be used.
• ISO must not be stored in an open container.
• The ISO pump reservoir must be kept filled with
applicable lubricant. The lubricant creates a barrier
between the ISO and the atmosphere.
• Only ISO compatible moisture-proof hoses must be
used.
• Reclaimed solvents, which may contain moisture,
must not be used.
• Solvent containers must be closed when not in use.
• Assemble threaded parts only with the correct
lubricant.
04.5 FOAM RESINS WITH 245 FA BLOWING
AGENTS
Some materials may become self-igniting if applied too
thick. Read material manufacturer's warnings and Safety
Data Sheet (SDS).
04.6 CHANGING MATERIALS
Prevent equipment damage and downtime during material
changes and flushes for service or storage.
• Flush equipment multiple times to make sure it is fully
clean.
• The fluid strainers must be cleaned after all flushes.
Speak with the material manufacturer for information
on chemical compatibility.
• When there is a change between epoxies, urethanes,
or polyureas, all wetted parts must be disassembled
and cleaned, and the hoses changed.
04.7 ELECTRICAL GROUND
Examine the local electrical code and Proportioner
manual for instructions on how to correctly ground the
equipment.
Ground the spray gun through a connection to a Binks
approved grounded fluid supply hose.
ISO that has started to cure will reduce the life and
performance of all wetted parts.
www.binks.com SI-347699 R3 (06/2025) 11 / 17 www.binks.comSI-347699 R3 (06/2025) PB / 17
EN EN 05. INSULATION REPLACEMENT
05. INSULATION REPLACEMENT
05.1 KIT CONTENTS
• K-Flex Titan Pipe Insulation (x2, 6 foot sections)
• 2 K-Flex Titan tape (12 feet)
• 2 x 36 yard black electrical tape
• Steel cable tie (x3)
05.2 HOSE DISASSEMBLY
1. Stretch the hose flat onto a level surface with access
to the modem in need of insulation repair as shown
as Figure A.
2. Remove the hose jacket approximately 10' upstream
of the modem, towards the machine.
3. Inspect the insulation between the modem and the
clamp and from the clamp upstream towards the
machine.
4. Remove the old insulation so there is approximately
5' of bare hose between the hose clamp and the start
of the old insulation.
5. Remove the (2) M4 bolts from the clamp assembly
using a 3mm hex wrench as shown in Figure B.
6. Separate the A hose from the B hose.
7. Clean off the bare hose using isopropyl alcohol and
then wipe down the hose with a clean towel.
Figure A
SAFETY
Use safety glasses during this procedure.
Figure B
www.binks.com SI-347699 R3 (06/2025) 13 / 17 www.binks.comSI-347699 R3 (06/2025) 12 / 17
EN EN05. INSULATION REPLACEMENT
05.2 HOSE ASSEMBLY
1. Take 2 inch electrical tape and wrap around the hose
approximately 1.5 from the clamp. This is upstream
of the modem in Figure C.
2. Wrap the tape around the hose and make sure to
keep the tape centered until its approximately 1/8
thick. This will create a ridge or barb that will allow
the insulation to stay stationary as shown in Figure D.
3. Wrap the insulation around the bare hose with one
end directly against the clamp. This will cover the
tape that was just installed as shown in Figure E.
Figure D
Figure E
Figure C
www.binks.com SI-347699 R3 (06/2025) 13 / 17 www.binks.comSI-347699 R3 (06/2025) 12 / 17
EN EN 05. INSULATION REPLACEMENT
4. Remove the film from the VHB™ tape along the
insulation slit as shown in Figure F. Then stick the
insulation back together as shown in Figure G.
5. Tape the insulation back together over the slit using a
6’ tape length as shown in Figure H and I.
Figure H
NOTICE
Make sure the slit has been completely closed.
Figure F
Figure G
Figure I
www.binks.com SI-347699 R3 (06/2025) PB / 17 www.binks.comSI-347699 R3 (06/2025) 14 / 17
EN EN05. INSULATION REPLACEMENT
6. Wrap the metal cable tie around the insulation and
tighten.
7. Wrap additional tape around the tightened zip tie to
protect all components against excessive wear as
shown in Figure K.
8. Tape the new insulation to the existing insulation as
shown in Figure L.
9. Repeat steps 7-15 on other side of hose.
10. Reconnect the hose clamp and make sure the cables
are routed through the center hole as shown in Figure
M.
11. Lay out the hose and organize the cables to allow for
best operation.
12. Reinstall the new jacket, modem boot and modem
jacket and then secure it to old jacket.
13. Repeat above steps on any other necessary
modems.
Figure J
Figure K
NOTICE
The edge of cable tie should be approximately ½
from the end of the insulation. The cable tie should be
tightened down between the hose clamp (solid yellow)
and the tape (dashed yellow) as shown in Figure J.
NOTICE
The old insulation may need to be compressed for the
new insulation to fit. Figure L
Figure M
EN 06. MANUAL REVISIONS
www.binks.com SI-347699 R3 (06/2025) 15 / 17
MANUAL CHANGE SUMMARY
Date Description Version
05/29/2024 Updated to latest format A
06/01/2025 Updated to Binks standard format B
06. MANUAL REVISIONS
EN06. MANUAL REVISIONS
www.binks.comSI-347699 R3 (06/2025) 16 / 17
This page intentionally left blank.
EN 07. WARRANTY
WARRANTY POLICY
This product is covered by Binks’ materials and workmanship limited warranty.
The use of parts or accessories from sources other than Binks will void all warranties. Failure to follow reasonable
maintenance guidance provided can invalidate the warranty.
For specific warranty information, please contact Binks.
For technical assistance or to locate an authorized distributor, contact one of our international sales
and customer support locations listed below.
www.binks.com SI-347699 R3 (06/2025) 17 / 17
REGION BINKS CONTACT
Americas Tel: 1-800-992-4657
Europe, Africa, Middle East Tel: +4401202571111
India marketingroa@binks.com
China Tel: +862133730108
Korea Tel: +82313663303
Japan Tel: +81457856421
Australia Tel: +61085257555
WARRANTY PAGE
07. WARRANTY
EN
Binks is a global leader in innovative finishing technologies.
Binks reserves the right to modify equipment specifications without prior notice.
Binks®, DeVilbiss® and Ransburg® are registered trademarks of Binks US, LLC.
©2025 Binks US, LLC. All rights reserved.
03 SAFETY
03.1 SAFETY PRECAUTIONS
03.2 ADDITIONAL SAFETY INFORMATION
04. IMPORTANT ISOCYANATE INFORMATION
04.1 General HANDLING GUIDELINES
04.2 Material Self Ignition
04.3 KEEP COMPONENTS A & B SEPARATE
04.4 EXPOSURE TO MOISTURE
04.5 foam resins with 245 FA blowing agents
04.6 changing materials
04.7 electrical ground
05. insulation replacement
05.1 hose disassembly
05.2 hose ASSEMBLY
06. manual revisions
07. warranty