- T-AGB COMPACT AUTO GUN Operation Manual [ Japanese ]
Important:Read and follow all instructions and SAFETY PRECAUTIONS before using this equipment.
DESCRIPTION
T-AGB gun is a small, light-weight Automatic Compact gun and suitable for robots and automatic machines.
Models and application information follows.
MODELS
Example: T-AGB-872-704-FX
Chart 1
Model No.
(Available Tip Sizes)
Gun body
Material
Fluid Tip/Needle
Material
Typical Applications Weight
T-AGB-862
AC(2.8), D(2.2), E(1.8),
FF(1.4), FX(1.1), G(0.7)
Aluminum 303Gr/ 400Gr Stainless Most conventional materials 270g
T-AGB-872
AC(2.8), D(2.2), E(1.8)
FF(1.4), FX(1.1), G(0.7)
303Gr
Stainless
303Gr/ 400Gr Stainless
Most conventional Materials &
most waterbornes &
chlorinated solvents.
550g
T-AGB-873
AC(2.8), D(2.2), EE(1.8)
FF(1.4)
303Gr
Stainless
Niteralloy Abrasive materials 550g
T-AGB-874
D(2.2), EE(1.8), FF(1.4)
303Gr
Stainless
Tungsten Carbide Porcelain Enamels 550g
T-AGB-879 FF(1.4), FX(1.1),
G(0.7)
303Gr
Stainless
303Gr Stainless Waterbornes 550g
T-AGB-882 FF(1.4), FX(1.1),
G(0.7)
316Gr
Stainless
303Gr Stainless Foods, Medicines 550g
NOTE: Stainless Steel body gun may be used with chlorinated solvents. Aluminum is not used in fluid passages. If using
chlorinated solvents, make sure all other fluid handling components are also compatible.
Basic Part Number Fluid Tip Size
Air Cap No.
T-AGB
COMPACT AUTO GUN Operation Manual
2
SAFETY PRECAUTIONS
This manual contains important information that ALL users should know and understand BEFORE using this equipment. This
information relates to USER SAFETY and PREVENTING EQUIPMENT PROBLEMS.
To help you recognize this information, we use the following terms to draw your attention to certain equipment labels and
portions of this manual. Pay special attention to any label or information that is highlighted by one of these terms:
WARNING
Important information to alert you to a situation that might cause serious injury or loss of life if instructions
are not followed.
CAUTION Important information that tells how to prevent damage to equipment.
NOTE Information that you should pay special attention to.
WARNING
The following hazards may occur during the normal use of this equipment. Please read the following chart.
HAZARD CAUSE SAFEGUARDS
Fire
Solvents and coatings can be highly
flammable or combustible, especially
when sprayed.
1. Adequate exhaust must be provided to keep
the air free of accumulations of flammable
vapors.
2. Smoking must never be allowed in the spray
area.
3. Fire extinguishing equipment must be
present in the spray area.
4. Static discharges must be prevented.
Ground(earth) all conductive objects in the
spray area, such as a cleaning solvent
bucket, fire extinguisher, etc.
5. When using solvents for cleaning:
• Those used for equipment flushing must
have a flash point equal to or greater than
that of the coating.
• Those used for general cleaning must
have flash points above 100°F (37.8°C).
Inhaling Toxic Substances
Certain materials may be harmful if
inhaled or if there is contact with the
skin.
1. Follow the requirements of the Material
Safety Data Sheet supplied by coating
material manufacturer.
2. Adequate exhaust must be provided to keep
the air free of accumulations of toxic
materials.
3. Use a mask or respirator whenever there is a
chance of inhaling sprayed materials. The
mask must be compatible with the material
being sprayed and its concentration.
Equipment must be as prescribed by an
industrial hygienist or safety expert, and be
NIOSH approved.
Explosion Hazard –
Incompatible Materials
Halogenated hydrocarbon Solvents-
for example:
methylene chloride and
1,1,1,-Trichloroethane are not
chemically compatible with the
aluminum that might be used in
many system components. The
chemical reaction caused by these
solvents reacting with aluminum can
become violent and lead to an
equipment explosion.
The T-AGB spray gun can be used with these
solvents.
However, aluminum is widely used in other
spray application equipment – such as material
pumps, cups, regulators, valves, etc. Check all
other equipment items before use of these
solvents. Read the label or data sheet for the
material you intend to spray. If in doubt as to
where or not a coating or cleaning material is
compatible, contact your material supplier.
3
HAZARD CAUSE SAFEGUARDS
General Safety Improper operation or maintenance
may create a hazard.
Operators should be given adequate training in
the safe use and maintenance of the equipment
(in accordance with the requirements of
NFPA-33, Chapter 15 in U.S.). Users must
comply with all local and national codes of
practice and insurance company requirements
governing ventilation, fire precautions, operation,
maintenance and housekeeping (in the U.S.,
these are OSHA Sections 1910.94 and
1910.107 and NFPA-33).
Noise Levels
The continuous A-weighted sound
pressure level of this spray gun may
exceed 85dB(A) depending on the
air cap/nozzle set-up being used.
Sound levels are measured using an
impulse sound level meter and
analyzer, when the gun is being used
in a normal spraying application.
Details of actual noise levels
produced by the various air
cap/nozzle set-ups are available on
request.
Wear earplugs when using the spray gun.
Spraying solvent
Pressured air/fluid passage may be
broken when cleaning or flashing
with solvent.
The solvent may be harmful if
contacted with eyes.
Always wear eye protection when spraying or
cleaning the equipment.
Misuse:
• All spray guns project particles at high velocity and must never be aimed t any part of body.
• Never exceed the recommended safe working pressure for any of the equipment used.
• The fitting of non-recommended or non-original accessories or spare parts may create hazardous conditions.
• Before dismantling the equipment for cleaning or maintenance, all pressures, air and material, must be isolated and
released.
Disposal of non-metallic materials must be carried out in an approved manner. Burning may generate toxic fumes.
The removal of waste solvents and coating materials should be carried out by an authorized local waste disposal service.
4
SPECIFICATIONS
Max. Air Pressure 0.9MPa (9.0 bar)
Max. Fluid Pressure 1.4MPa (14.0 bar)
Cylinder Air Pressure Min. 0.34MPa (3.5 bar)
Max. 0.49MPa (5.0 bar)
Weight 270g (T-AGB-862) 550g (Stainless Body Type)
Gun Stud Diameter 10.5mm
Fluid Thread R1/8 (F)
CAP Thread R1/8 (F)
FAN Thread R1/8 (F)
CYL Thread: R1/8 (F)
INSTALLATION
Figure 1. Dimensions
Figure 2. Installation
Mount the gun with the stud (21) or tighten with M8(F) of the gun body.
CAUTION:
The air supplied to the gun should be clean air that removed any impurities. Also, the air hose should have enough inner
diameter depending on the length to supply necessary air.
As CYL air is not consumption air, large diameter of the tube is not necessary.
When circulating the paint, remove the plug and install the fluid nipple.
5
OPERATION
1. Mix, prepare and strain the coating material to be sprayed according to paint manufacturer’s instructions.
2. Adjust the CYL air at 0.34~0.49Mpa.
3. Turn the Adjusting Screw (20) counter-clockwise 3.5 turns from fully closed position and fixed with Lock Nut (19).
This makes the Needle fully opened.
4. Adjust the CAP/FAN air at about 0.35Mpa.
5. Adjust fluid air at about 0.07Mpa~0.1Mpa.
6. Turn on CYL air and test spray. Adjust fluid and air pressure until desired pattern is obtained. Control fluid pressure at
source supply. Always attempt to keep CAP pressure as low as possible to minimize overspray.
WARNING
Risk of injury. Equipment and fluid may be under pressure. Pressure in the system must be relieved before beginning the
cleaning procedure and before replacing any parts. Follow the procedures in the literature provided with the system.
CLEANING
1. Relieve air pressure from pressure tank. Carefully follow instructions in bulletin sent with tank.
2. Replace material in container with a suitable solvent.
3. Re-pressurize system.
4. Trigger gun and repeat procedure until gun and hose are thoroughly clean. A SolventSaver™ type hose and gun cleaner
which supplies a mixture of air and solvent can be used to most effectively clean gun and hose internal passages. See
Accessories for SolventSaver™. Wipe exterior of gun with a solvent dampened cloth.
5. If a recirculating system is used, it may be necessary to fit a shut off valve in return line to ensure fluid tip and forward
portion of sprayhead passage are properly cleaned when flushed with solvent.
CAUTION
Do not totally submerge gun in solvent. It is possible to wash solids into air operating sections of gun which could seriously
damage piston O Ring seals.
CAUTION
The air cap can be immersed in solvent for cleaning. If orifices are clogged, use a broom straw or toothpick to remove
obstruction. Never use a steel wire or hard instrument. This will damage air cap and result in a distorted spray pattern.
6
REPLACEMENT
Tools Required
Crescent Wrench
1/2 Box Wrench (for Item No. 3)
Pliers (for Needle Assy)
3, 6, 13, 14mm Open Wrench (for Item No. 12, 17, 21, 15)
1.5mm Hex Wrench (for Item No. 16)
T-AGB-GRT-1 (for Item No. 7)
T-AGB-HW-1 (for Item No. 11)
Fluid Tip (3)
1. Relieve all air and fluid pressure in system.
2. Remove Adjusting Screw (20), Lock Nut (19) and Needle Spring (18) and Needle Assy with Pliers from gun body.
3. Remove Retaining Ring (1) and Air Cap (2).
4. Remove Fluid Tip (3) with 1/2 Box Wrench and also remove Nozzle Gasket (22).
5. Reassemble in reverse order. The taper side of inside of Nozzle Gasket (22) should be faced to Fluid Tip side when
assembling. Recommended torque of Fluid Tip: 24~27N.m. (for T-AGB-862, the recommended torque is 16~20 N.m.).
NOTE
It is recommended that Fluid Tip (3), Nozzle Gasket (22), Needle (12), Needle Seal Kit (7), and Piston Cup (14) be replaced
at the same time.
Replacing Needle (12), Piston Cup (14)
1. Remove Adjusting Screw (20), Lock Nut (19), Needle Spring (18). Pull Needle Assy out from gun body with Pliers.
2. Loosen Set Screw (16) of Retainer (15) by turning 1~2 times with 1.5mm Hex Wrench.
3. Loosen Piston Flange (13) and Retainer (15) a little by turning clockwise with 14mm Spanner for Retainer (15) and 6mm
Spanner for Lock Nut (17).
4. Fix this position with Set Screw (16). Remove Retainer (15) with 14mm Spanner and Lock Nut with 6mm Spanner.
5. Using 14mm Spanner for Retainer (15) and 3mm Spanner for Needle (12), remove Needle (12) from Piston Flange (13).
6. Loosen Set Screw (16) with Hex Wrench and remove Piston Flange (13) and Retainer (15), then remove Piston (14).
CAUTION
Do not try to remove Needle (12) with Lock Nut (17) installed as it may cause the damage.
Reassembling Needle Assy
1. Apply small amount of liquid gasket on thread of Needle (12) and screw into Piston Flange (13). Then insert Piston Cup
(14) and screw into Retainer (15) fully by finger.
2. Using 14mm Spanner on Retainer (15), tighten it approximately 150~180 degree clockwise from the position where
maximally screwed in with finger with 3mm Spanner on Needle (12).(when exchanging to new Piston Cup)
CAUTION
If Piston Cup is not brand-new, tighten at 60~90 degree. (Recommended torque: 0.8~1.0N・m)
3. Tighten Set Screw (16) with 1.5mm Hex Wrench.
4. Using14mm Spanner on Retainer (15) and then tighten Lock Nut (17) with 6mm Spanner.
(Recommended torque: 0.8~1.0N・m)
7
Replacing Needle Seal Kit (7), Seal (9)
1. Remove Adjusting Screw (20), Lock Nut (19), Needle Spring (18) and Needle Assy with Pliers from gun body.
2. Remove Fluid Seal Kit (7) with T-AGB-HW-1 Housing Wrench (Optional).
3. To remove Seal (9) inside of Needle Seal Kit (7), remove Gland (11) with T-AGB-GRT-1 Grand Removal Tool (Optional).
(Refer to Figure 3)
Figure 3. Removing Gland (11) Figure 4. Assembling Needle Seal Kit
Holding③ with 13mm Spanner,
①place the Spacer, ②tighten the bolt and extract Gland
(11).
Place Seals (9) and Gland (11) as shown the above.
Press them in with plastic board from both side.
4. Bind seal tape 1.5 laps on thread of Housing (10). Careful not to cover the hole in front of the thread.
5. Set Needle Seal Kit (7) on the shaft of T-AGB-HW-1 Housing Wrench and assemble on Gun Body (6).
Tighten as follows.
① Screw Needle Seal Kit (7) with T-AGB-HW-1 Housing Wrench from the backside of the Gun Body (6).
② Pressure 0.1Mpa on fluid inlet. (For circulating system, close the one side.)
③ Press the point of Fluid Tip (3) to stop the air and tighten until the air stops leaking from 3mm hole.
6. Apply petroleum jelly on Piston Cup (14) of Needle Assy and insert into gun.
7. Insert Needle Spring (18), Lock Nut (19) and assemble Adjusting Screw (20) at the position of 3.5 counter-clockwise turns
from fully closed position.
8. Pressure 0.34Mpa on CYL and check the movement of needle.
Figure 5. Gun Exploded View
Plastic Board Plastic Board
(9) (9)
(10)
(11)
NOTE
A nozzle gasket (22) is assembled in
this gun to avoid accumulating paint
between fluid nozzle and gun body.
Also, a fluid plug (23) is included
together with 1/8 plug to fill either of
two fluid inlets which is not used.
8
Item No. Part Number Description Q’ty
872, 873, 874 Stainless Steel Body
1 MBC-368 Retaining Ring 1
2 see chart Air Cap 1
3 see chart Fluid Tip 1
5 MBC-142-1 Plastic Baffle 1
6 T-AGB-71 Gun Body (303Gr Stainless) 1
7 T-AGB-10-1 Needle Seal Kit 1
8 T-AGB-11-3 Seat Washer 2
9 T-AGB-12 Seal 1
10 T-AGB-13-2 Housing 1
11 T-AGB-14 Grand 1
12 see chart Needle 1
13 T-AGB-101 Piston Flange 1
14 T-AGB-102 Piston Cup 1
15 T-AGB-103 Retainer 1
16 T-AGB-104-K5 Set Screw Kit of (5) 1
17 T-AGB-105 Lock Nut 1
18 T-AGB-106 Needle Spring 1
19 T-AGB-127 Lock Nut (SUS) 1
20 T-AGB-128 Adjusting Screw (SUS) 1
21 T-AGB-109 Gun Stud 1
22 T-AGB-120-K5 Nozzle Gasket Kit of (5) 1
23 T-AGB-121-K5 Fluid Plug Kit of (5) 1
■Tools
T-AGB-GRT-1 Grand Removal Tool 1
T-AGB-HW-1 Housing Wrench 1
862 Aluminum Body
19 T-AGB-117 Lock Nut (Aluminum) 1
20 T-AGB-118 Adjusting Screw (Aluminum) 1
879 All Stainless Body
1 T-MBC-368-SUS Retaining Ring 1
7 T-AGB-10-1-SUS Needle Seal Kit 1
10 T-AGB-13-2-SUS Housing 1
11 T-AGB-14-SUS Grand 1
13 T-AGB-101-SUS Piston Flange 1
15 T-AGB-103-SUS Retainer 1
17 T-AGB-105-SUS Lock Nut 1
21 T-AGB-109-SUS Gun Stud 1
882 High Grade (SUS-316) Stainless Steel Body
1 T-MBC-368-SUS T-AGB-109-SUS 1
7 T-AGB-10-1-SUS Needle Seal Kit 1
10 T-AGB-13-2-SUS Housing 1
11 T-AGB-14-SUS Grand 1
13 T-AGB-101-SUS Piston Flange 1
15 T-AGB-103-SUS Retainer 1
17 T-AGB-105-SUS Lock Nut 1
21 T-AGB-109-SUS Gun Stud 1
9
Item No. Part Number Description Q’ty
Air caps
2 ■Air Cap with Ring 1 pcs.
MB-4039-62 AC(2.8mm)
MB-4039-64 D(2.2mm)
MB-4039-67 E, EE (1.8mm)
2 ■Air Cap without Ring 1 pcs.
AV-1239-265R-1 Resin
AV-1239-704
AV-1239-705
AV-1239-765
31767-777
AV-1239-797
Fluid Tip & Needle for 872, 862, 879, 882
3 ■Fluid Tip (300Gr Stainless, with soft-seat) Stamped No.: AV-4915 1 pcs.
AV-651-D 2.2mm
AV-651-E 1.8mm
AV-651-FF 1.4mm
AV-651-FX 1.1mm
AV-651-G 0.7mm
AV-645-AC 2.8mm
12 Needle (300Gr Stainless for 872, 862)
T-JGA-402-DEX (for AV-651-D)
T-JGA-402-E (for AV-651-E)
T-JGA-402-FZ (for AV-651-FF, FX)
T-JGA-402-G (AV-651-G)
Fluid Tip & Needle for 874 (Tungsten)
3&12 ■Lapped Set (Tungsten Fluid Tip & Needle)
T-AGB-440-FF-TC 1.4mm (AV-617-FF,T-JGA-409-FF)
T-AGB-440-EE-TC 1.8mm (AV-617-EE,T-JGA-409-EE)
T-AGB-440-D-TC 2.2mm (AV-617-D,T-JGA-409-D)
Fluid Tip & Needle for 873 (Niteralloy)
3&12 ■Lapped Set (Niteralloy Fluid Tip & Needle)
T-AGB-440-FF-TF 1.4mm (AV-611-FF,T-JGA-402-FF-TF)
T-AGB-440-EE-TF 1.8mm (AV-611-EE,T-JGA-402-NADEEE)
T-AGB-440-D-TF 2.2mm (AV-611-D,T-JGA-402-NADEX)
T-AGB-440-AC-TF 2.8mm (AV-611-AC,T-JGA-402-AC-TF)
10
SERVICE CHECK
problem Cause Correction
Will not spray. No pressure to gun.
Piston stops moving.
Check air and material lines.
Check CYL air pressure.
Improper spray pattern. A. Gun not adjusted properly.
A, B. Material build up on the air cap (2)or fluid
tip (3).
A. Re-adjust. See Operation Section.
A, B. Clean the air cap or fluid tip. See
Preventive Maintenance.
Note
To determine where the material build up is, rotate the air cap 180°and test spray. If the pattern
stays in the same position, the condition is caused by material build up on the fluid tip. If the pattern
changes with air cap movement, the buildup is in the air cap.
C, D. Wrong material or material too thick.
D. Insufficient material or atomizing air
pressure too high.
C, D Adjust material pressure or thin material.
D. Increase material or reduce atomizing
air pressure.
Jerky or fluttering spray
1. Insufficient material in the tank or an obstruction
in the line.
2. Gun material passage plugged.
3. Worn Needle Seal Kit (7).
4. Loose or damaged Fluid Tip.
1. Fill tank or clear obstruction.
2. Clean.
3. Replace.
4. Tighten or replace.
Air leaking from
Adjusting Screw (20).
1. Damaged or worn Piston Cup (14).
2. Damaged cylinder of Gun Body (6).
1. Replace.
2. Replace.
Dripping from Fluid Tip. 1. Worn or damaged Fluid Tip (2) or Needle (12).
2. Needle Spring (18) damaged or deformed.
1. Replace.
2. Replace.
Air or fluid leaking from
Gun Body (6).
Damaged or worn Needle Seal Kit (7) Replace.
ACCESSORIES
OM_AG_T-AGB-E01_2025.04
Code No. Part No. Description
805153 SSL-10-K12 Gun Lube Kit of (12)
806472 42884-214-K5 Cleaning Brush Kit of 5
800163 GC-100-K48 Gun Cover Kit of (48)
HD-505 Quick Cleaner
800279 QMGZ-5200 Solvent Saver (10)
The proper combination of fluid pressure, fan and atomization air pressure,
and fluid tip size should result in a pattern of this shape.
Normal spray pattern