- IR Smart Oven 04-501-01 [ English ]
• Direct Heat Transfer
• High-Efficiency (short ovens and
operating costs)
• Instant Heat Output Control
• 0-100% Temperature Control
• Separate Zones (flexibility and
energy savings)
• Self-Cleaning Interior
• No Pre-Heat
PRIMARY FEATURES:
• Independently Controllable Infrared
Heat Zones
• Closed Loop Temperature Controls
(PLC with operator interface screen)
• Built-in Pyrometer Temperature Sensor
(calibration panels included)
• Four Modes of Operational Control
• Pre-Mounted Exhaust Blower
Electric Infrared
Curing Solutions
The IR Smart lab oven was designed to test your coatings and
processes in your own facility. This oven will demonstrate the
many benefits of electric infrared for drying and curing.
Binks created the IR Smart lab oven to provide valuable
data to aid in the process development and support of your
infrared curing customers. The oven is designed to provide an
accurate and repeatable testing environment.
IR Smart Oven
THE IR SMART DIFFERENCE
• Control
• Repeatability
• ± 2% Temperature Accuracy
• High Efficiency
IR Smart Oven
A powerful solution can start with a simple conversation
We want to help build the best solution to your application challenges. Learn more about what
we can offer by reaching out to the office nearest you.
For more information,
visit binks.com. ©2025 Binks.
Models and specifications subject to
change without notice. All rights reserved.
Form No. 04-514-01
Americas 1.800.992.4657 marketing@binks.com
EMEA 44.0.120 257.1111 marketing-eu@binks.com
China 86.21.33730108 mkt_cn@binks.com
Japan Sales Office 81.45.785.6421 jp-rans-tokyosales@binks.com
Japan Binks/DeV 81.45.785.6421 jp-binks-devi@binks.com
India/SE Asia 44.0.120 257.1111 marketing-roa@binks.com
OPERATING MODES
Enter desired % power output and the desired amount of
time. The temperature the panel achieves is the variable
(up to 20 steps possible).
Enter desired % power output and the desired panel
temperature. The time it takes the panel to reach
temperature is the variable (up to 20 steps possible).
A PID control algorithm ramps the part temperature to
set-point via operator defined maximum power output
rate (slow or fast). The power output required to maintain
part temperature is the variable (up to 20 steps possible).
Manual
SPECIFICATIONS
TE
M
P
TIME
TE
M
P
TIME
TE
M
P
TIME
CLOSED LOOP CONTROL
TE
M
P
TIME
CLOSED LOOP CONTROL
FAST RAMP
SLOW RAMP
Size 43.25 W × 54.81 H × 33.0 D (1099mm×1392mm×838mm)
Weight 425 pounds (193 Kg)
Test Panel Size 10 × 14 (254mm × 356mm) Maximum
Heat Zones Top and Bottom (controlled independently)Operating Modes
Power 480 / 3Ø / 60 Hz • 44 amps • 28 kW (alternate voltages available)
Lamps (24) 1550 T3 Short-Wave • 290 volt
Product Temperature 500°F (high temperature options available)
CURING PAINT....... IT’S WHAT WE DO.
Time/Power
Power/Temp
Time/Temp