Resource Library
JCK Manual
- JCK Manual EN [ English ]
- JCK Manual JA [ Japanese ]
JCK
Operation Manual
2
JCK ― Air Cap ― Fluid Tip and Type of Feed (G: Gravity, S: Suction, P: Pressure)
(Ex.): JCK-LV2-13P ← (JCK - LV2 Air Cap - Fluid Tip I.D. 1.3mm, Pressure Feed)
Maximum Working Air Pressure: 0.69 MPa Maximum Working Fluid Pressure: 0.69 MPa
Fluid Inlet :G1/4 Air Inlet:G1/4
Chart. 1
Type of Feed
Air Cap Name
Part No.
Fluid Tip I.D.
(mm)
Air Inlet Pressure
(MPa)
Air Consumption
(ℓ/min)
Fluid Output
(mℓ /min)
Fan Pattern Size
(mm)
Gun Weight
(g)
Gravity
SS1
JCK-3-SS1
0.8 0.1 80 ★50 ★120
290
SS3
JCK-3-SS3
1.3
0.24 145
160 170
1.5 200 180
1.8 250 190
ST1
JCK-3-ST1
1.0
0.2 240
★100 ★220
1.3 135
240 1.5 165
1.8 200
Suction
SS3
JCK-3-SS3
1.3
0.24 145
120 130
1.5 160 150
1.8 185 180
ST1
JCK-3-ST1
1.3
0.2 240
95 180
1.5 115 190
1.8 140 210
Pressure
CN1
JCK-3-CN1
0.8/1.0/
1.3/1.5
0.24 220
100 160
200 210
300 260
LV1
JCK-3-LV1
0.8/1.0/1.3 0.2 230
100 150
200 200
300 250
LV2
JCK-3-LV2
0.8/1.0/1.3 0.2 230
100 200
200 270
300 320
Chart. 2
Ref No. Part No. Description Qty Ref No. Part No. Description Qty
1 JCK-6 RETAINING RING ASSY 1 11 JCK-14-K5 NEEDLE SPRING 1
2 See Chart.1 AIR CAP 1 12 JCK-13 NEEDLE ADJUST SCREW 1
3 JCK-440-XX FLUID TIP & NEEDLE SET 1 13 JCK-463 NEEDLE PACKING ASSY 1
4 JCK-7 BAFFLE ASSY 1 14 JCK-108 TRIGGER SET 1
5 JUP-8-K5 BAFFLE GASKET 1 15 JCK-42 CHEATER VALVE ASSY 1
6 JCK-35 FLUID INLET SET 1 16 JCK-30 AIR CONNECTER 1
7 No parts sold GUN BODY 1
8 JCK-44 PATTERN VALVE ASSY 1
9 JCK-443 AIR SEALS & AIR VALVE SET 1
10 JCK-12 AIR VALVE BUSHING ASSY 1
Note) Ref No.5 and No.11 are sold in packs of 5 pieces.
Ref No.2: ex. JCK-3-ST1
Ref No.3: ex. JCK-440-13 (Fluid Tip I.D. = 1.3mm)
Chart. 3 *Sold separately
Ref No. Part No. Description
17 LUNA2-34 AIR SEAL INSERTION TOOL
- SSL-10 Gun Lube (60mL)
- JCK-100 REPAIR KIT
MODELS
SPECIFICATIONS
PARTS LIST
Fig.1
ACCESSORIES
3
In this part sheet, the words WARNING, CAUTION and NOTE are used to
emphasis important safety information as follows:
⚠ WARNING ⚠ CAUTION NOTE
Hazards or unsafe practices which could
result in severe personal injury, death or
substantial property damage.
Hazards or unsafe practices which could
result in minor personal injury, product or
property damage.
Important installation, operation or
maintenance information.
⚠ WARNING
Read the following warnings before using this equipment.
SOLVENTS AND COATING MATERIALS. Can be
highly flammable or combustible when sprayed.
Always refer to the coating material supplier's
instructions and safety sheets before using this
equipment.
INSPECT THE EQUIPMENT DAILY. Inspect the
equipment for worn or broken parts on a daily basis.
Do not operate the equipment if you are uncertain
about its condition.
READ THE MANUAL. Before operating finishing
equipment, read and understand all safety, operation
and maintenance information provided in the operation
manual. Users must comply with all local and national
codes of practice and insurance company
requirements governing ventilation, fire precautions,
operation, and housekeeping of working areas.
EQUIPMENT MISUSE HAZARD. Equipment misuse
can cause the equipment to rupture, malfunction or
start unexpectedly and result in serious injury.
FIRE AND EXPLOSION HAZARD. Never use
1,1,1-Trichloroethane, Methylene Chloride, other
Halogenated Hydrocarbon solvents or fluids containing
such solvents in equipment with aluminum wetted
parts. Such use could result in a serious chemical
reaction, with the possibility of explosion. Consult your
fluid suppliers to ensure that the fluids being used are
compatible with aluminum parts.
GLOVES. Must be worn when spraying or cleaning
the equipment.
WEAR SAFETY GLASSES. Failure to wear safety
glasses with side shields could result in serious eye
injury or blindness.
STATIC CHARGE. Fluid may develop a static charge
that must be dissipated through proper grounding of
the equipment, objects to be sprayed and all other
electrically conductive objects in the dispensing area.
Improper grounding or sparks can cause a hazardous
condition and result in fire, explosion or electric shock
and other serious injury.
WEAR RESPIRATOR. The use of respiratory
protective equipment is recommended at all times.
The type of equipment must be compatible with the
material being sprayed.
TOXIC VAPOURS. When sprayed, certain materials
may be poisonous, create irritation, or are otherwise
harmful to health. Always read all labels, safety sheets
and follow any recommendations for the material
before spraying. If in doubt, contact your material
supplier.
NEVER MODIFY THE EQUIPMENT. Do not modify
the equipment unless the manufacturer provides
written approval.
LOCK OUT / TAG-OUT. Failure to de-energies,
disconnect, lock out and tag-out all power sources
before performing equipment maintenance could
cause serious injury or death.
PROJECTILE HAZARD. You may be injured by
venting liquids or gases that are released under
pressure or flying debris.
NOISE LEVELS. The A-weighted sound level of
pumping and spray equipment may exceed 85 dB(A)
depending on equipment settings. Actual noise levels
are available on request. It is recommended that ear
protection is worn at all times while equipment is in
use.
PRESSURE RELIEF PROCEDURE. Always follow
the pressure relief procedure in the equipment
instruction manual.
KNOW WHERE AND HOW TO SHUT OFF THE
EQUIPMENT IN CASE OF AN EMERGENCY.
HIGH PRESSURE CONSIDERATION. High pressure
can cause serious injury. Relieve all pressure before
servicing. Spray from the gun, hose leaks or ruptured
components can inject fluid into your body and cause
extremely serious injury.
OPERATOR TRAINING. All personnel must be
trained before operating finishing equipment.
IT IS THE RESPONSIBILITY OF THE EMPLOYER TO PROVIDE THIS INFORMATION TO THE OPERATOR OF THE EQUIPMENT.
4
1. Daily lubrication and cleaning are necessary to maintain the best condition of the gun.
2. To clean the gun body, wipe exterior with solvent or cleaning solution dampened cloth.
Do not immerse the gun in a solvent or cleaning solution as it may damage the gun or
cause painting problems.
3. After using the gun, remove the paint and then pass an appropriate solvent or cleaning
solution through the paint path to wash away any remaining paint.
4. Do not leave any solvent or cleaning solution in the paint path or paint cup. It may cause
corrosion or damage.
5. The AIR CAP (2) can be immersed in solvent and brushed down for cleaning. If orifices
are clogged, use a toothpick to remove obstruction. Never use a steel wire or hard
instrument. This will damage air cap and result in a distorted spray pattern.
6. The following portions should be lubricated regularly (➡ in Fig.2); Sliding points of
TRIGGER SET(14), PATTERN VALVE ASSY (8), CHEATAR VALVE ASSY (15),
NEEDLE ADJUST SCREW (12), AIR VALVE (9-4), and NEEDLE (3-2).
For lubrication, SSL-10 Gun Lube* is recommended. (*Sold separately, contains NO
silicones or petroleum distillates.)
Do not lubricate to any portion where not instructed.
7. When installing AIR CAP (2), make sure no foreign materials adhered on RETAINING
RING ASSY (1) and thread of body and then oil one drop of Gun Lube SSL-10. (⇒ in Fig.2)
8. Apply non-silicone grease lightly on NEEDLE SPRING (11) and AIR VALVE SPRING
(9-5). Do not apply too much grease as it may clog the air passage.
Before replacing gun parts, remove materials from the gun for cleaning. Then release the air pressure of the gun and remove all hoses
and paint containers. Perform the replacement work in a clean place and fix the gun properly. Use the appropriate tools indicated for
replacement of parts. After replacing the parts, operate the gun and check that the replaced parts are functioning properly.
FLUID TIP & NEEDLE SET (3)
1. Loosen completely PATTERN VALVE ASSY (8) knob by turning the knob counterclockwise.
2. Remove NEEDLE ADJUST SCREW (12) and NEEDLE SPRING (11) and then withdraw NEEDLE (3-2).
3. Remove RETAINING RING ASSY (1) and AIR CAP (2).
4. Remove FLUID TIP (3-1) by using 19mm wrench.
5. Clean the seal surface on the GUN BODY side and tighten a new FLUID TIP with a torque wrench (recommended tightening torque:
8N-m).
6. Insert a new NEEDLE and NEEDLE SPRING and install the NEEDLE ADJUST SCREW.
FLUID INLET (6), AIR CONNECTOR (16)
FLUID INLET SET (6) and AIR CONNECTOR (16) are fixed together by sealing material. Do not remove these parts if you do not need them,
as they may cause damage.
PATTERN VALVE ASSY (8), CHEATER VALVE ASSY (15)
Disassembling and reassembling PATTERN VALVE ASSY (8) and CHEATER VALVE ASSY (15) by using 13mm wrench. When disassembling
and reassembling, turn the knobs completely counterclockwise.
AIR SEALS & AIR VALVE SET (9)
1. Remove NEEDLE ADJUST SCREW (12) and NEEDLE SPRING (11) and then withdraw NEEDLE (3-2).
2. Remove AIR VALVE BUSHING (10) by using 14mm wrench.
3. Withdraw VALVE SPRING (9-5), AIR VALVE (9-4).
4. Withdraw VALVE SEAT (9-3). Be careful not to damage the seal surface on the GUN BODY side.
5. Remove LOCK SCREW (9-2) by using 7mm hex wrench. Be careful not to damage the seal surface on the GUN BODY side.
6. Push the AIR SEAL (9-1) toward the back of the GUN BODY to remove it.
7. Remove the AIR SEAL (9-6) inside the AIR VALVE BUSHING. Be careful not to damage the seal surface on the AIR VALVE BUSHING side.
Do not reuse the removed AIR SEALS & AIR VALVE SET.
8. Install the new AIR SEALS & AIR VALVE SET in the reverse procedure of removal, being careful not to damage it.
The separately sold AIR SEAL INSERTION TOOL (17) is convenient for inserting the AIR SEALS (9-1, 3, 6).
9. Install the NEEDLE, NEEDLE SPRING and NEEDLE ADJUST SCREW.
NEEDLE PACKING ASSY (13)
1. Remove NEEDLE ADJUST SCREW (12) and NEEDLE SPRING (11) and then withdraw NEEDLE (3-2).
2. Remove NEEDLE PACKING ASSY (13) by using 10mm wrench.
3. Install a new NEEDLE PACKING ASSY. Use a 10mm wrench to tighten it until it stops lightly first, and then tighten it about 1/16 turn.
4. Install the NEEDLE, NEEDLE SPRING and NEEDLE ADJUST SCREW.
Fig.2
PREVENTIVE MAINTENANCE
REPLACEMENT OF PARTS
5
Problem Cause Correction
Will not spray No air or material is supplied to the gun.
CHEATER VALVE ASSY (15) nob is not properly adjusted.
NEEDLE ADJUSTING SCREW (12) is not properly adjusted.
Check air and material lines.
Adjust accordingly.
Adjust accordingly.
Improper spray pattern
A, B: Material build-up on the AIR CAP (2) or FLUID TIP (3-1).
A, B: AIR CAP (2) or FLUID TIP (3-1) damaged.
C, D: Incorrect fluid delivery or viscosity.
C, D: Incorrect air pressure.
Clean the AIR CAP or FLUID TIP.
Replace.
Adjust fluid delivery and viscosity.
Adjust air pressure.
Intermittent or fluttering spray Insufficient material in the cup or loose Connector.
Partially obstructed fluid passage or hose.
Loose FLUID TIP (3-1).
Material build-up on the seating on FLUID TIP (3-1) and GUN BODY (7).
Damaged FLUID TIP (3-1).
Fill material or tighten the Connector.
Clean or replace.
Tighten.
Clean.
Replace.
Fluid leaking from
NEEDLE PACKING ASSY (13)
Worn or damaged NEEDLE PACKING ASSY (13).
Worn or damaged NEEDLE (3-2).
Replace.
Replace.
Dripping from FLUID TIP (3-1) Material build-up on the seating on FLUID TIP (3-1) and NEEDLE (3-2).
Worn or damaged FLUID TIP (3-1) or NEEDLE (3-2).
NEEDLE PACKING ASSY (13) and NEEDLE (3-2) are stuck together.
Loose NEEDLE ADJUST SCREW (12).
Clean.
Replace.
Clean and lubricate.
Adjust accordingly.
OM_HG_JCK-E01_2025.05
TROUBLE SHOOTING
JCKスプレーガン取扱説明書
重要:本機器のご使用前に必ず2頁警告をお読みの上、正しくお使いください。取扱説明書は大切に保管してください。
型式
JCK ― エアキャップ ― フルイドチップ口径 と 供給方式 (G:重力式,S:吸上式,P:圧送式 )
例: JCK-LV2-13P (JCK-LV2エアキャップ–1.3mm口径フルイドチップの圧送式)
仕様
最大供給エア圧力:0.69MPa 最大供給液体圧力:0.69MPa
フルイドインレット:G1/4 エアインレット:G1/4
表 1
塗装条件:手元エアレギュレーター=HARG-510 塗料粘度=20sec(IHS) 吹付距離=200mm
供給方式
エアキャップ名称
部品番号
フルイドチップ
口径(mm)
手元エア圧力
(MPa)
エア消費量
(ℓ/min)
吐出量
(㎖/min)
パターン幅
(mm)
本体重量
(g)
G:重力式
ST1
JCK-3-
ST1
1.3
0.2 240
135
240
290
1.5 165
1.8 200
S:吸上式
ST1
JCK-3-
ST1
1.3
0.2 240
95 180
1.5 115 190
1.8 140 210
P:圧送式
LV2
JCK-3-
LV2
1.3/1.5/1.8 0.2 230
100 200
200 270
300 320
部品リスト
表 2
項番 部品番号 部品名称 使用数
項番 部品番号 部品名称 使用数
1 JCK-6 リテーニングリング クミ 1 11
JCK-14-
K5
ニードルスプリング 1
2 表1参照 エアキャップ 1 12 JCK-13 ニードルアジャストスクリュー 1
3
JCK-440-
XX
フルイドチップ&ニードル セット 1 13 JCK-463 ニードルパッキン クミ 1
4 JCK-7 バッフル セット 1 14 JCK-108 トリガー セット 1
5 JUP-8-K5 バッフルガスケット 1 15 JCK-42 チーターバルブ クミ 1
6 JCK-35 フルイドインレット セット 1 16 JCK-30 エアコネクタ 1
7 パーツ販売無し ガンボディ 1
8 JCK-44 パターンバルブ クミ 1
9 JCK-443 エアシール&エアバルブ セット 1
10 JCK-12 エアバルブブッシング クミ 1
注)項番5と項番11は、各々5個入りでパーツ販売しています。
項番2の例:JCK-3-ST1
項番3の例:JCK-440-13 は1.3㎜口径です。
アクセサリー
表 3 ※別売り
項番 部品番号 部品名称
17 LUNA2-34 エアシール挿入工具
- SSL-10 スプレーガンオイル(60mL)
- JCK-100 リペアキット
2
重要な安全情報を強調するために、警告、注意、および注記という言葉が使用されます。
❚❛❜ 警告 ⚠ 注意 注記
重傷、死亡または重大な物的損害
につながる危険な行為。
軽傷、製品の破損または物的損害
につながる危険な行為。
設置、操作もしくはメンテナンス
に関する重要な情報。
❚❛❜ 警告
本機器を使用する前に、以下の警告をお読みください
溶剤および塗料。スプレーすると、可燃性が高くなり非
常に燃えやすくなります。スプレーガンを使用する前に、
塗料メーカーの説明書および安全シートを必ずお読みく
ださい。
日常点検してください。摩耗や破損している部品が無
いか点検してください。機器に健全性に確信が持てな
い状態で使用しないでください。
マニュアルをお読みください。操作する前に、取扱説明
書に記載されている安全・操作・メンテナンスに関する全
ての情報を読み、理解してください。使用者は、地域や国
または保険会社などが定める換気・火災予防・作業エリ
アの保守管理などの規範を厳守する必要があります。
機器の誤用の危険。機器の誤用により、機器の破損や
誤作動、予期しない作動で重傷を負う可能性がありま
す。
火災と爆発の危険。トリクロロエチレン、メチレンクロライ
ド、その他のハロゲン化炭化水素溶剤を使用しないでく
ださい。これら溶剤を含む液体を使用すると、ガン本体・
カップに使用されているアルミニウムと化学反応を生
じ、爆発する可能性があります。使用する液体に疑問が
ある場合は、液体メーカーに問い合わせ、使用されてい
る液体がアルミニウムパーツに対応している事を確認し
てください。
保護手袋。機器をスプレーまたは洗浄する際は、必ず保
護手袋を着用してください。
保護メガネを着用してください。サイドシールド付きの
保護メガネを着用しない場合、目に重傷を負う、もしく
は失明につながる恐れがあります。
静電気。液体は静電気を発生させる可能性があります。
機器・被塗物・および塗装領域内のすべての導電性物質
を適切に接地してください。不適切な接地は危険な状態
を引き起こし、火災・爆発・感電やその他の重大な傷害を
引き起こす可能性があります。
呼吸用保護具を着用してください。常に呼吸用保護具
を使用されることをお勧めします。呼吸用保護具のタイ
プは、スプレーする液体に適したものをご使用くださ
い。
有毒な蒸気。特定の物質は、スプレーにより毒性や刺激
性を生じ、人体に害を及ぼす可能性があります。スプレ
ーする塗料のラベルと安全シートを読み、注意事項に従
ってください。不明な点がある場合は、材料の供給元に
問い合わせてください。
機器を改造しないでください。取扱説明書に書かれて
いないような改造をしないでください。
ロックアウト/タグアウト。機器のメンテナンスを行う前
に、すべての電源を切断し、ロックアウト/タグアウトしな
いと、重傷や死亡事故を引き起こす可能性があります。
投射物の危険。圧力のかかった液体や気体によって飛
ばされる破片などにより負傷する可能性があります。
ノイズレベル。ポンプおよびスプレー装置のノイズレベル
は、設定により85dBを超える場合があります。 実際の
騒音レベルは、希望に応じて調整可能です。機器使用中
は、常に耳栓を着用して保護されることをお勧めしま
す。
圧力を開放する方法。必ず機器の取扱説明書に記載さ
れている手順で圧力開放してください。
緊急時に備え、機器をどこでどのように停止・遮断す
るかを把握しておいてください。
高圧の考慮。高圧は重大な怪我を引き起こす可能性があ
ります。修理点検を行う前に、全ての圧力を開放してく
ださい。ガンからのスプレー、ホースの漏れ、破裂した部
品により、体内に流体が入ると、極めて深刻な重症を引
き起こす可能性があります。
作業者のトレーニング。機器を操作する前に、作業者
は、トレーニングを受ける必要があります。
本情報をこの機器の使用者に提供することは、雇用主の責任となります。
3
保守
1. ガンは最良な状態で使用できるよう毎日清掃と潤滑を実施してください。
2. ガンボディの汚れは、溶剤や洗浄液を浸したウエスで拭き取ってください。ガンの破損、塗装
上のトラブルにつながりますので、ガンを溶剤や洗浄液に浸さないでください。
3. ガンの使用後は、塗料等を取り除いた後、塗料経路に適切な溶剤や洗浄液を通し、残った塗
料等をきれいに洗い流してください。
4. 塗料経路や塗料カップ内に溶剤や洗浄液を残さないでください。腐食や破損の原因になり
ます。
5. エアキャップ(2)は外して溶剤や洗浄液につけておき、ブラシで汚れを落としてください。穴
がつまっている場合は、つまようじで清掃するようにし、決して針金等硬いものを使用しない
でください。エアキャップの傷は、わずかでもパターンを乱す原因となります。
6. 図2➡指示箇所には定期的に注油してください。トリガー セット(14)、パターンバルブ クミ
(8)、チーターバルブ クミ(15)、ニードルアジャストスクリュー(12)、エアバルブ(9-4)、ニ
ードル(3-2)の各摺動箇所。
7. エアキャップを取付ける時に、リテーニングリング(1)のネジ部(図2⇒指示箇所)にゴミが
つかないように注意し、注油してください。
※シリコンや石油留分を含まない、別売りのスプレーガンオイルSSL-10をお勧めします。
※指示されている箇所以外には注油しないでください。
8. ニードルスプリング(11)とエアバルブスプリング(9-5)は非シリコン系のグリスを少量塗布してください。グリスの付け過ぎは塗装上のトラブルにつ
ながります。
部品の交換
ガンの部品交換をされる前にガンの塗料を抜き、洗浄してください。次にガンのエア圧力を抜き、全てのホース、塗料カップを取り外してください。
交換作業は清潔な場所で行い、ガンを適切に固定してください。部品交換は明記された適切な工具をご使用ください。部品交換後はガンを操作し
て、交換した部品が正しく機能している事をご確認ください。
フルイドチップ&ニードル セット(3)
1. パターンバルブ クミ(8)のつまみを左回し一杯に緩めます。
2. ニードルアジャストスクリュー(12)、ニードルスプリング(11)を取り外し、ニードル(3-2)を抜き取ります。
3. リテーニングリング クミ(1)、エアキャップ(2)を取り外します。
4. フルイドチップ(3-1)を19mmのレンチを使用して取り外します。
5. ガンボディ側のシール面を洗浄し、新しいフルイドチップをトルクレンチ(規定締め付けトルク:8N-m)で締め付けます。
6. 新しいニードルとニードルスプリングを差し込み、ニードルアジャストスクリューを取り付けます。
フルイドインレット セット(6)、エアコネクタ(16)
フルイドインレット セット(6)とエアコネクタ(16)は、シール材により固定されています。破損の原因になる可能性がありますので、必要で無い場
合は、これらの部品を取り外さないでください。
パターンバルブ(8)、チーターバルブ(15)
パターンバルブ(8)、チータバルブ(15)は、ツマミを左廻し一杯に緩めてから、13mmレンチを使用し分解、組付けを行ってください。
エアシール&エアバルブ セット(9)
1. ニードルアジャストスクリュー(12)とニードルスプリング(11)を取り外し、ニードル(3-2)を抜き取ります。
2. エアバルブブッシング(10)を14mmのレンチを使用して取り外します。
3. エアバルブスプリング(9-5)、エアバルブ(9-4)を抜き取ります。
4. バルブシート(9-3)をガンボディ(7)側のシール面を傷つけないよう取り外します。
5. ロックスクリュー(9-2)を7㎜の六角レンチを使用して取り外します。ガンボディ側のシール面を傷つけないよう注意してください。
6. エアシール前(9-1)をガンボディ後方に押し出して取り外します。
7. エアバルブブッシング内のエアシール後(9-6)を取り外します。エアバルブブッシング側のシール面を傷つけないよう注意してください。
※取り外したエアシール&エアバルブ セットは再利用しないでください。
8. 新しいエアシール&エアバルブ セットを、傷をつけないように注意しながら、外した時と逆の手順で取り付けます。
※エアシール(9-1,3,6)の挿入には、別売りのエアシール挿入工具(17)が便利です。
9. ニードル、ニードルスプリング、ニードルアジャストスクリューを取り付けます。
ニードルパッキン クミ(13)
1. ニードルアジャストスクリュー(12)とニードルスプリング(11)を取り外し、ニードル(3-2)を抜き取ります。
2. ニードルパッキン クミ(13)を10mmのレンチを使用して取り外します。
3. 新しいニードルパッキン クミを取り付けます。10mmレンチを使用して最初に軽く止まるまで締めた後、1/16回転程度締め込んでください。
4. ニードルを差し込みます。※安全に注意し、ニードルがトリガーに干渉しないよう確認しながら、真っすぐ強めに押し込んで下さい。
5. ニードルスプリング、ニードルアジャストスクリューを取り付けます。
図2
4
トラブルシューティング
現 象 原 因 対 策
スプレーできない ガンにエアもしくは塗料が供給されていない。
チーターバルブ クミ(8)のつまみが適切に調整されていない。
ニードルアジャストスクリュー(12)が適切に調整されていない。
エアと塗料の供給を確認
調整
調整
不良パターン
A,B: エアキャップ(2)もしくはフルイドチップ(3-1)が汚れている。
A,B: エアキャップ(2)もしくはフルイドチップ(3-1)に損傷がある。
C,D: 吐出量もしくは塗料粘度が適切ではない。
C,D:空気圧が適切ではない。
洗浄
交換
調整
調整
息つぎ 塗料が不足している。
塗料継手が緩んでいる。
塗料経路が部分的に詰まっている。
フルイドチップ(3-1)が緩んでいる。
フルイドチップ(3-1)とガンボディ(7)のシート面が汚れている。
フルイドチップ(3-1)が損傷している。
補給
増し締め
洗浄もしくは交換
増し締め
洗浄
交換
ニードルパッキン(13)から
塗料漏れ
ニードルパッキン クミ(13)が緩んでいる。
ニードルパッキン クミ(13)が摩耗もしくは損傷している。
ニードル(3-2)が摩耗もしくは損傷している。
増し締め
交換
交換
フルイドチップ(3-1)先端から
塗料漏れ
フルイドチップ(3-1)、ニードル(3-2)のシール部が汚れている。
フルイドチップ(3-1)、ニードル(3-2)が摩耗もしくは損傷している。
ニードルパッキン クミ(13)とニードル(3-2)が固着している。
ニードルアジャストスクリュー(12)が戻され(開き)過ぎている。
洗浄
交換
洗浄と注油
調整
OM_HG_JCK-J02_2025.05