- CAMAIR DAD-PRO 服务手册 [ 英语 ]
DAD-PRO™ DESICCANT AIR DRYER ASSEMBLY
PARTS LIST
Ref
No.
Replacement
Part No. Description Individual
Parts Req.
1 130505
Humidity Indicator
(1 Humidity Indicator
Paper Included)
1
2 130510 Gasket 1
*3 130504 Desiccant Cartridge
(Not Shown) 1
4 CT-101 Tank Grommet
(Not Shown) 1
*The Safety Data Sheet (SDS-1) is available upon request.
DESCRIPTION
The desiccant air dryer is designed to be a point of use system.
It is capable of removing dirt, water, and water vapor from
compressed air. The cartridge has a housing material that acts
like a coalescer and final filter.
SPECIFICATIONS
Air Inlet 1/2 NPT (Female)
Air Outlet 1/2 NPT (Female)
Air Flow Capacity 30 CFM
Maximum Operating
Pressure
200 PSIG (14 Bar)
Maximum Temperature 150° F (65.6° C)
Humidity Indicator �Green: OK
Yellow: Replace Desiccant
Water Vapor Removal -40° F Dew Point
Particle Removal 0.1 micron
INSTALLATION
Risk of personal injury. Risk of property damage.
! WARNING
Except as otherwise specified by the manufacturer, this
product is specifically designed for compressed air service and
use with any other fluid (liquid or gas) is a misapplication. For
example, use with or injection of certain hazardous gases in
the system (such as oxygen or liquid petroleum gas) could be
harmfull to the unit or result in a combustible condition that may
cause fire or explosion. Manufacturer's warranties are void
in the event of misapplication and manufacturer assumes no
responsiblity for any resulting loss.
Risk of equipment damage! Do not install your DAD-PRO™
unit where it is subject to sudden depressurization cycles
exceeding 20 PSIG. Quick relieving air solenoid valves, typical
in some spray booths, will eventually produce desiccant
dusting.
Risk of injury. Release all air pressure from system before
servicing system. Use only specified Camair parts.
! WARNING
Risk of personal injury. Risk of property damage.
! WARNING
2
Air Outlet
Air Inlet
3
Not Shown
(inside tank)
Not Shown
(inside tank)
4
1
DAD-PRO™
LA-2752
Air In
SERVICE MANUAL EN®
SB-6-234-R3
EN
SB-6-234-R3 (08/2025)2 / 4www.binks.com
INSTALLATION (continued)
To minimize sudden depressurization effect, replace the
existing solenoid with a slow closing solenoid valve. (One
source; Automatic Switch Co.) Or, install an air adjusting valve
at the existing solenoid outlet.
1. �Choose a location in your existing air piping as close to
the point of use, such as inside the spray booth and as far
from your compressor as possible. The air entering the
dryer must not exceed 100° F. You can check this by putting
your hand on the compressed air line where you want to
install the dryer, if the pipe is not uncomfortably hot the
temperature is satisfactory. Install at a height so that the top
flange can be easily removed to replace the desiccant.
2. �With your air compressor shut off and locked out in
accordance with OSHA regulations, and your compressed
air system depressurized, install into the compressed air
line. The installation of a manual bypass or a 1/2 NPT ball
valve before the dryer is recommended.
3. �Mount the dryer to the wall using the brackets and pipe
the dryer into the air system. Do not depend on the pipe to
support the dryer.
4. �If you have a pressure regulator at the same location as the
dryer, it should be mounted after the dryer.
5. �Complete the piping of the dryer and you are ready to enjoy
moisture free, particle free and oil free compressed air at
your chosen point of use application.
OPERATION
Your dryer is completely automatic and requires maintenance
only when the desiccant cartridge needs replacing.
MAINTENANCE
Risk of injury. Components are under pressure. Relieve air
pressure before performing any maintenance.
! WARNING
1. �Replace the Desiccant Cartridge when the humidity indicator
turns yellow.
2. �Shut off the air compressor, lock it out in accordance with
OSHA regulation and depressurize the compressed air line
serving the dryer by opening the drain on the dryer.
3. �Remove the top flange.
4. �Take out the used Desiccant Cartridge and dispose of
properly. Inspect and/or replace the bushing located on the
inside of the tank at the outlet port. Be sure to press it into
place before installing a new desiccant cartridge. Install new
cartridge.
5. �Put DeVilbiss gun lube on the screw threads and reinstall
the top flange on the desiccant tank , torque screws to
25-30 ft. lbs. You are now ready to place the dryer back
into service.
6. �The built in humidity indicator should turn back to green
within 12 hours. If it doesn't, this means liquid water has
gotten on the indicator and washed away the litmus solution
that allows the indicator to change color, if this happens you
will need to replace the humidity indicator with a new one.
Risk of injury. Only use a socket wrench to remove the humidty
indicator from the desiccant tank. Immediately replace the
humidity indicator if damaged.
! WARNING
EN
SB-6-234-R3 (08/2025) 3 / 4 www.binks.com
NOTES
SB-6-234-R3 (08/2025)4 / 4www.binks.com
WARRANTY POLICY
This product is covered by Binks’ materials and workmanship limited warranty.
The use of parts or accessories from sources other than Binks will void all warranties.
Failure to follow reasonable maintenance guidance provided can invalidate the warranty.
For specific warranty information, please contact Binks.
For technical assistance or to locate an authorized distributor, contact one of our
international sales and customer support locations listed below.
REGION BINKS CONTACT WARRANTY PAGE
Americas Tel: 1-800-992-4657
Europe, Africa, Middle East Tel: +4401202571111
India marketingroa@binks.com
China Tel: +862133730108
Korea Tel: +82313663303
Japan Tel: +81457856421
Australia Tel: +61085257555
Binks is a global leader in innovative finishing technologies.
Binks reserves the right to modify equipment specifications without prior notice.
Binks®, DeVilbiss® and Ransburg® are registered trademarks of Binks US, LLC.
®
EN WARRANTY
©2025 Binks US, LLC. All rights reserved.
For additional information or copies of your service manual, please visit us online at:
binks.com/en/library
Or use this QR code with your mobile device:
Obey local or municipal regulations for product recycling and disposal.
English