- JGX-502 매뉴얼 EN [ 영어 ]
- JGX-502 매뉴얼 JA [일본어] [ 일본어 ]
Important:Read and follow all instructions and SAFETY PRECAUTIONS before using this equipment
Description
The JGX-502 Spray Gun is a conventional air spray gun, patterned after the JGA series, whose functions are similar to
standard air spray gun models. The gun is available in three types: gravity feed, suction feed, and pressure feed, in order to
cover the widest range of applications.
With all areas of the fluid passages made from stainless steel, the JGX-502 can be used with a wide range of paints, with the
only exception being those of a highly corrosive and/or abrasive nature. The use of such materials will require thorough
cleaning and frequent part replacement.
Any questions regarding the operation of the JGX Spray Gun should be directed to us or our distributors BEFORE use.
MODELS
JGX-502 - Air Cap No. - Fluid Tip Size – Type of Feed
(Ex.): JGX-502-143-FF-G
This represents a gun with a number 143 Aircap, a Size FF Fluid Tip, and set up for Gravity Feed.
SPECIFICATIONS
Air and Fluid Inlet Threads:
Fluid Suction/Pressure Feed
PF3/8 Male, standard
PF1/4 Male, Optional
Air Inlet PF1/4
Weight Suction/Pressure Feed 440g
OPERATION
Before using the gun, the needle packing, which is shipped loose to avoid binding, should be adjusted.
The packing gland (Part#7) should be gradually screwed clockwise while triggering the gun up to the point where the needle
does not smoothly return to the closed-position. At this point the packing gland should be slightly loosened by screwing it in
counter-clockwise so that needle moves freely.
Adjust the atomizing air pressure to the lowest level possible and commensurate with proper atomization quality desired, to
minimize overspray and maximize paint transfer efficiency.
The spray gun should be used at all times perpendicular to the surface to be coated at a distance of 150-200mm.
JGX-502 Spray Gun
Operation Manual
2
Maintenance
The gun should be cleaned and lubricated daily to maintain daily to maintain its optimum performance. Clean the paint
passages thoroughly by spraying solvents through the gun after use.
The gun body should never be soaked in the solvent for cleaning. Exterior surface should only be wiped with solvent
dampened rags.
The air caps should be detached from the gun and soaked in the solvent.
Use toothpicks to remove any paint build up from the aircap holes. NEVER use metal objects to clean the aircaps in order to
avoid damage to the fine holes, which will cause the spray pattern to become distorted.
A drop of lubricant should be applied regularly to the trigger bearing stud (#25), the stem of the air valve assembly(#21), and
the needle packing gland (#7). For optimum results use SSL-10 Spray Gun Oil.
The Needle Spring (#11) and the Air Valve Spring (#22) should be lightly greased. Do not lubricate or grease excessively in
order to avoid clogging in the air passages.
REPLACEMENT OF PARTS
A wrench (JGX-34) is provided with the gun.
When replacing the fluid tips, ensure that the Fluid Needle Adjustment Screw is moved, and also ensure that the Spreader
Valve is in the fully open (counterclockwise) position.
Whenever the Fluid Inlet Nipple (#23) or the Air Inlet Nipple (#28) are replaced, a sealant material such as Loctite 242, should
be applied to the thread before inserting it into the gun body. The same sealant should also be used on the body thread of the
Spreader Valve (#13) and the Cheater Valve (#27).
Chart 1 : Aircap-Fluid Tip Combination
Aircap Fluid Tip Size
No. on CAP Code Part No. Gun Type GY FX FF EX
103
143
165
803737
803739
803740
JGX-3-103
JGX-3-143
JGX-3-165
S,G
S,G
P
V
V
V
V
V
V
Chart 2 :Selection of the Fluid Tip and the Needle
Fluid Tips Fluid Needles Gun Type
No. on CAP Size(mm) Code Part No. Code Part No.
GY
FX
FX
FF
FF
EX
0.8
1.1
1.1
1.4
1.4
1.8
803775
803786
803747
803787
803748
803749
JGX-4-GY
JGX-401-FX
JGX-4-FX
JGX-401-FF
JGX-4-FF
JGX-4-EX
803750
803751
803751
803752
803752
803753
JGX-41-GX
JGX-41-FX
JGX-41-FX
JGX-41-FF
JGX-41-FF
JGX-41-EX
G,S
G,P
S
G,P
S
G,S
Notice : The fluid tip of Suction Feed gun and GY Tip (0.8m/m) is not with soft-seat.
Chart 3 :Fluid Inlet Description
Paint Supply Thread Code Part No. Remarks
S,P
S,P
G
PF3/8
PF1/4
PF1/4
803767
803768
803769
JGX-1
JGX-35
JGX-2
------
optional
------
3
PARTS LIST
# Code Part No. Description pcs # Code Part No. Description pcs
1 803736 JGX-5 Retaining Ring 1 13 803760 JGX-44 Spreader Valve Assy. 1
803735 JGX-6 Retaining Ring, brass(Optional) 1 17 803764 JGX-43 Air Valve Assy. 1
2 See Chart1 Air Cap 1 19* ----- ----- Packing 1
3 See Chart2 Fluid Tip 1 20* ----- ----- O-Ring 1
4 803741 JGX-7 Baffle 1 22 803778 JGX-25 Spring 1
5* 803783 JGX-8-K5 Gasket (a set of 5 pcs.) 1 23 See Chart3 Fluid Inlet Nipple 1
6* 803855 JGV-463 Needle Packing (2piece) 1 24 803916 JGS-108-1 Trigger 1
7 803784 JGX-11-K3 Packing Gland (a set of 3pcs.) 1 25 803567 JGX-45-K5 Bearing Stud (a set of 5pcs.) 1
8* ----- ----- Gasket 1 26* 805281 JGX-46-K10 Circlip (a set of 10pcs.) 1
9 803745 JGX-12 Bushing 1 27 803771 JGX-42 Cheater Valve Assy. 1
10 See Chart2 Fluid Needle 1 28 803772 JGX-30 Air Inlet Nipple 1
11 803785 JGX-14-K3 Needle Spring (a set of 3pcs.) 1 29 803773 JGX-34 Wrench 1
12 803759 JGX-13 Adjusting Screw 1 803733 JGX-101 Repair Kit 1
ACCESSORIES
OM_HG_JGX-502-E01_2025.05
Part No. Description Part No. Description
TLC-555 1Suction Cup (with PTFE Coated Inner Lining) HD-505-W 5 Gun & Hose Cleaner
KG-400 400cc Side Cup with Stand (Gravity Feed) JGX-101 Repair Kit
KG-400-T
400cc Side Cup with Stand (with PTFE Coated
Inner Lining, Gravity Feed)
SSL-10
Spray Gun Lubricant. Silicone-free,
Non-petroleum product
KB-555 KB-555 2 Pressure Feed Remote Cup HAF-507 Disposable Air Line Filter
KR-470-1 700cc Suction Cup Assembly
JGX-502 は、JGA のような大型機なみのスプレー性能を備えた小型・
軽量の汎用ハンドスプレーガンで、広い用途に適応できるよう、吸上式、
圧送式、重力式(横カップ)の各機種をそろえ、塗料流通部のステン
レス化も実現しました。
JGX-502 は、ほとんどの一般塗料に使用することができますが、著しく腐
食性の強いものや、摩耗性の強い塗料に使用できるようには設計され
ておりません。もし、このような塗料にご使用の場合には、徹底的な洗浄
を頻繁に行わなければなりませんし、また、部品交換の頻度が高くなる
ことを覚悟しなければなりません。
ご使用になる塗料について、何か疑問のある場合には事前に取扱
店にお問い合わせください。
型 式・仕 様
■型式の表し方
表 1:ガンの型式選定表
エアキャップ フルイドチップサイズ 塗料
供給 刻印 コード 部品番
号
GY
(0.8)
FX
(1.1)
FF
(1.4)
EX
(1.8)
103 803737 JGX-3-
103
〇 ― ― ― G
143 803739 JGX-3-
143
― 〇 〇 〇 G
143 803739 JGX-3-
143
― ― 〇 〇 S
165 803740 JGX-3-
165
〇 〇 〇 ― P
表 2:フルイドチップ詳細とフルイドニードルの組合せ
塗料
供給
フルイドチップ詳細 フルイドニードル
口
径
刻印 コード
番号
部品番号 刻
印
コード
番号
部品番
号
G 0.8 GY 803775 JGX-4-GY GY 803750 JGX-41-
GX
G/P 1.1 FX-S 803786 JGX-401-
FX
FX 803751 JGX-41-
FX
G/P 1.4 FF-S 803787 JGX-401-
FF
FF 303752 JGX-41-
FF
S 1.1 FX 803747 JGX-4-FX FX 803751 JGX-41-
FX
S 1.4 FF 803748 JGX-4-FF FF 803752 JGX-41-
FF
G/S 1.8 EX 803749 JGX-4-EX EX 803753 JGX-41-
EX
・JGX-401-FX/FF ソフトシート付フルイドチップは、吸上式タイプの
ガン に使用できません。
操 作
新しいガンを使いはじめる前には、念のため、ニードルパッキンの調
整 をしなおしてください。パッキングランド(7)を少しずつ絞め込みな
がら、トリガーでニードルを引いたり戻したりして、ニードルの戻りの悪く
なるところまで行ったらそこからほんの少しだけ、パッキングランドを緩め
てください。
エア圧の調整は、塗着効率を良くするために、必要な範囲でできる
だけ低い圧力に設定されるようおすすめします。また、均一な
仕上がりを得るため、スプレーガンには常に塗面に垂直 に保持し
吹付距離は 150 ~ 200mm でお使いください。
保 守
ガンをいつも最良の状態で使用できるよう、毎日、清掃と潤滑を
実施してください。塗料通路内の洗浄は、余分な塗料を除いた
あと、適当な溶剤を通して残留塗料をすべて洗い流してください。
ガンボディの汚れは、溶剤に浸したウェスで拭くだけにし、ガンを
丸ごと溶剤に浸さないように注意してください。
エアキャップは、外して溶剤に浸けておきます。もし、キャップの
穴が詰まっている場合は、つまようじを使って清掃してください。
この場合、針や堅い材料のものを使用しますと傷をつける事もあ
りますので、絶対に避けてください。キャップのわずかな傷でも、パ
ターンを乱す原因となります。
ベアリングスタッド(25)、エアバルブクミ(17)の慴動部および
ニー ドル(10)のパッキングランド(7)に出入りする部分に毎日オ
イル(SSL-10 スプレーガンオイルをお使いください) を 1 滴差してく
ださい。また、ニードルスプリング(11)エアバルブスプリング(22)には、
時々グリース(非シリコン系のもの)を薄く塗ってください。グリース
の付け過ぎは、エアの通路を詰まらせる原因になりますのでご注
意ください。
部品交換
フルイドチップの取り付け、取り外しには専用レンチ(JGX-34)または、
21mm のメガネレンチをお使いください。
また、アジャストスクリュー(12)を取り外し、トリガー(24)を引いて、フル
イドニードル(10)を後退させておいてください。
フルイドチップを締め付けるときは、パターンバルブは必ず全開の状
態(後退させておく)にしておくよう注意してください。
フルイドインレット(23)エアコネクター(28)を交換するときには、
ネジ部とテーパー面に適当なシール剤(ロックタイト 242 等)を塗って
締め付けてください。なお、パターンバルブ(13)、チータバルブ(27)の
組立のときにも、同様にネジ部にシール剤を付けて固定してください。
表 3:フルイドインレットの種類
塗料供給 ネジ径 コード番
号
部品番号 備考
S ・ P
PF3/8 803767 JGX-1
PF1/4 803768 JGX-35 オプション
G PF1/4 803769 JGX-2
JGX-502
スプレーガン取扱説明書
■仕 様
・接続ネジ 塗料入口 重力式 PF 1/4
吸上式・圧送式 PF 3/8 (標準)
PF 1/4 (オプション)
エア入口 PF 1/4
・重 量 吸上式・圧送式 440g
重力式 430g
表 4.JGX-502 パーツリスト
参照
番号
コード
番号 部品番号 部品名 個数
参照
番号
コード
番号 部品番号 部品名 個数
1 803736 JGX-5 リテーニングリング 1 17 803764 JGX-43 エアバルブクミ 1
803735 JGX-6 リテーニングリング(真鍮製、オプション) 1 20 * ――― ――― O-リング 1
2 表1 参照 エアキャップ 1 22 803778 JGX-25 スプリング 1
3 表2 参照 フルイドチップ 1 23 表3 参照 フルイドインレット 1
4 803741 JGX-7 バッフル 1 24 803916 JGS-108-1 トリガー 1
5 * 803783 JGX-8-K5 ガスケット(5 個入) 1 25 803567 JGX-45-K5 ベアリングスタンド(5 個入) 1
6 * 803855 JGV-463 ニードルパッキン(2 ピース) 1 26 * 805281 JGX-46-K10 サークリップ(10 個入) 1
7 803784 JGX-11-K3 パッキングランド(3 個入) 1 27 803771 JGX-42 チータバルブクミ 1
8 * ――― ――― ガスケット 1 28 803772 JGX-30 エアコネクター 1
9 803745 JGX-12 ブッシング 1 29 803773 JGX-34 スパナー 1
10 表2 参照 フルイドニードル 1 803733 JGX-101 リペアキット 1
11 803785 JGX-14-K3 ニードルスプリング(3 個入) 1
12 803759 JGX-13 アジャストスクリュー 1
13 803760 JGX-44 パターンバルブクミ 1
* 印のパーツは、ガンのオーバーホールに必要なパッキンやガスケット類で、お手許に常備しておくことをおすすめします。
なお、JGX-101 リペアキットには、これらのパーツがすべて(ガン 1 丁分)含まれています。
( 注 ) 部品番号の最後に -K5、-K10 とあるのは、それぞれ 5 個入キットを表します。
アクセサリー
KG-400 重力式カップ(横カップ)、 容量 400cc KB-555 圧送式リモートカップ、常用 2.0kgf/㎠まで、
容量約2ℓ
KG-400-T KG-400 の内面にテフロンコートしたもので、
洗浄が非常に簡単です
SSL-10 スプレーガンオイル・シリコン・石油製品を含まず、
安心してお使いいただけます
KG-250 重力式カップ(横カップ)、容量250cc HAV-501-B エア調節バルブ(ゲージ付)
KR-470-1 700cc
TLC-555 吸上式ドリップフリー、内面テフロンコート付カッ
プ、容量1000cc
OM_HG_HGX-502-J06_2025.05